Queratoplastia Lamelar Anterior Profunda asistida con láser de femtosegundo configuración Zig-Zag: Resultados a un año de seguimiento / Deep Anterior Lamellar Keratoplasty in a Zig-Zag Pattern Assisted by Femtosecond Laser: 1 year follow up
Rev. Soc. Colomb. Oftalmol
; 50(1): 10-16, 2017. ilus., tab.
Article
en Es
| LILACS, COLNAL
| ID: biblio-885101
Biblioteca responsable:
CO119
RESUMEN
Objetivo:
Reportar el desenlace luego de 12 meses de seguimiento, en pacientes en los que se realizó una queratoplastia lamelar anterior profunda (DALK) asistida con láser de femtosegundo.Metodología:
Se realizó un estudio descriptivo, retrospectivo, mediante revisión de historias clínicas de pacientes sometidos a DALK asistida con láser de femtosegundo (Wavelight FS-200 ® Alcon. Forth Worth, Texas), utilizando la configuración de zig-zag. Las indicaciones de DALK incluyeron queratocono, ectasia post LASIK y leucoma como secuela de queratitis infecciosa. Las variables estudiadas fueron agudeza visual mejor corregida, cilindro queratométrico, refracción final y complicaciones intra y post operatoria.Resultados:
En total se incluyeron 10 ojos de 10 pacientes, en todos los ojos se llevó a cabo con éxito femto-DALK y no hubo ninguna complicación intra operatoria. En el postoperatorio se presentó un caso de rechazo estromal, un caso de hipertensión ocular secundario a esteroides y un caso de retraso en la cicatrización. El seguimiento promedio fue de 13, 1 meses (R= 12 15 meses). La Agudeza Visual Mejor Corregida (AVMC) preoperatoria promedio fue LogMAR 0,96 (R= 0,54 1,60). La AVMC postoperatoria promedio a los 12 meses fue 0,10 (R= 0,00 0,17). El equivalente esférico preoperatorio medio fue -12,6 Dioptrias (D) (R= -5,0 a -15,0D) y el postoperatorio fue -2,57 D (R= -0,50 a -6,25 D). El astigmatismo queratométrico preoperatorio medio de -11.5D (R= -7.0 a -23D) y el postoperatorio -2,4 D (R= -0,75 a -3,75 D).Conclusión:
La femto-DALK en confi guración Zig-Zag es un procedimiento confiable, con baja tasa de complicaciones intra y postoperatorias. El resultado refractivo es comparable con la queratoplastia penetrante, y ofrece beneficios sobre factores de estabilidad biomecánica y recuperación del paciente en el primer año postoperatorio.ABSTRACT
Objective:
The aim was to report the surgical outcomes of twelve months follow-up aft er femtosecond laser assisted Zig-zag configuration combined with Deep Anterior Lamellar Keratoplasty (Femto-DALK).Methods:
A descriptive, retrospective study, which evaluated and assisted medical records of patients who had undergone deep anterior lamellar keratoplasty (DALK) femtosecond laser assisted. Ten eyes of ten consecutive patients underwent femtosecond (Wavelight FS-200 ® Alcon. Forth Worth, Texas) laser-assisted zig-zag configuration combined with Anwar´s big-bubble technique DALK, from April 2012 to December 2013. The diagnosis of the patients were keratoconus, corneal ectasia and scarring following infectious keratitis. Variables measured were Best corrected visual acuity, keratometric corneal cylinder, final refraction and intraand postoperative complications were analyzed.Results:
The procedure was performed without any complications in all patients. There was only a single case of stromal graft rejection, a case of corticosteroidinduced ocular hypertension and a case of delayed corneal epithelial healing. Mean follow-up period was 13.1 months (R= 1215 months). The mean preoperative BCVA was LogMAR 0,96 (R= 0,54 1,60). Th e mean postoperative BCVA at 12th month was 0,054 (R= 0,00 0,09). The mean preoperative spherical equivalent (SE) was -12,6 Diopter (D)(R= -5,0 to -24,0D) and postoperative SE was -2,50 D (R=-0,50 to -6,25 D). The measurements of keratometric corneal cylinder preoperative was -11.5D (R= -7.0 a -23D) and postoperative refractive cylinder was -2,4 D (R=-0,75 to -4,00 D).Conclusion:
Laser-assisted zig-zag configuration combined with Anwar´s big-bubble technique DALK is a safe procedure. The rate of intra and postoperative complications is low. The refractive outcomes are comparable to penetrating keratoplasty, but better biomechanical stability of the cornea and a faster visual recovery with femtoDALK procedure.Palabras clave
Texto completo:
1
Índice:
LILACS
Asunto principal:
Trasplante de Córnea
Tipo de estudio:
Observational_studies
Límite:
Humans
Idioma:
Es
Revista:
Rev. Soc. Colomb. Oftalmol
Asunto de la revista:
OFTALMOLOGIA
Año:
2017
Tipo del documento:
Article