Continuous versus interrupted suture technique in microvascular anastomosis in rats
Acta cir. bras
;
32(9): 691-696, Sept. 2017. tab, graf
Artículo
en Inglés
| LILACS
| ID: biblio-886235
ABSTRACT
Abstract Purpose:
To compare the continuous and interrupted suture technique on femoral artery on rats after vessel repair and 14 days after.Methods:
Twenty rats were operated randomly divided into two group matched according to the suture technique used interrupted or continuous. We performed a femoral anastomosis on the right femoral artery. We analyzed weight, arterial caliber, anastomosis time and patency after vessel repair and 14 days after.Results:
There was no significant difference between groups in the weight (p=0.64), diameter of the femoral artery (p=0.95) and patency (p=1.00). The time spent in the anastomosis was 451 seconds in the continuous group and 718 seconds in the interrupted group, presenting significant difference (p<0.01).Conclusion:
The continuous suture technique shows a similar patency rates than interrupted technique, however with a shorter time to perform the anastomosis.
Texto completo:
Disponible
Índice:
LILACS (Américas)
Asunto principal:
Técnicas de Sutura
/
Arteria Femoral
/
Microcirugia
Límite:
Animales
Idioma:
Inglés
Revista:
Acta cir. bras
Asunto de la revista:
Cirugía General
/
Procedimentos Cir£rgicos Operat¢rios
Año:
2017
Tipo del documento:
Artículo
País de afiliación:
Brasil
Institución/País de afiliación:
Universidade do Estado do Pará/BR
Similares
MEDLINE
...
LILACS
LIS