Criterios de calidad de dispersiones radiactivas en radiosinovectomía / Quality criteria of the radiopharmaceutical suspensions used in radiosynoviorthesis
Cruz Arencibia, Jorge; Cruz Morales, Amed; Izquierdo Pérez, Jorge; Morín Zorrilla, José.
  • Cruz Arencibia, Jorge; Centro de Isótopos. Mayabeque. CU
  • Cruz Morales, Amed; Centro de Isótopos. Mayabeque. CU
  • Izquierdo Pérez, Jorge; Centro de Isótopos. Mayabeque. CU
  • Morín Zorrilla, José; Centro de Isótopos. Mayabeque. CU
Nucleus (La Habana) ; (62): 34-37, jul.-dic. 2017. ilus
Artículo en Español | LILACS | ID: biblio-895145
RESUMEN
En el trabajo se examinan los criterios de calidad de dispersiones radiactivas utilizadas en radiosinovectomía a partir de los requisitos recogidos en la farmacopea para el Fosfato Crómico- de la firma Mallinkrodt, las recomendaciones de uso de radiofármacos registrados de la Asociación Europea de Medicina Nuclear y datos aportados por las firmas comercializadoras. Tomando como base el estudio de dos formulaciones propias de Fosfato Crómico, una marcada con y la otra, con , en las que se estudia la consistencia (reproducibilidad) tanto de la pureza radioquímica como de la distribución de tamaños de partículas, se prueba que el tenor de 5 % de fosfato libre admitido en la formulación de la firma Mallinkrodt y que se extendiera a formas iónicas de otros radiofármacos de matrices diferentes, se debe probablemente al efecto inevitable de la esterilización a vapor sobre la suspensión y de que tanto al momento de decidir sobre el empleo de un lote, como en los requisitos de las farmacopeas, debiera prestarse más atención a la distribución de tamaños por estar más vinculada a la eficacia y seguridad de los radiofármacos
ABSTRACT
The quality criteria of radioactive dispersions used in radiosynovectomy are examined, taking into account the requirements of the Pharmacopoeia for the Chromic Phosphate P-32 of Mallinckrodt, recommendations for the use of approved radiopharmaceuticals of the European Association of Nuclear Medicine and data provided by others marketing firms. The behavior of two formulations of chromic phosphate, one -labeled and the second -labeled, from the point of view of the consistency (reproducibility) of both the radiochemical purity and the particle size distribution was assayed. It is proven that the presence of 5% of free phosphate admitted in the Mallinckrodt formulation, and extended to the presence of ionic forms of other radiopharmaceuticals of different matrices, is probably due to the inevitable effect of steam sterilization on the suspension. Based on these results and the accumulated clinical experience, it is considered that to establish the quality requirements of the radioactive suspensions for radiosynovectomy, more attention should be paid to the particle size distribution than to the percentage of free ionic forms. The first one is more related to the efficacy and safety of this kind of radiopharmaceuticals

Texto completo: Disponible Índice: LILACS (Américas) Tipo de estudio: Guía de Práctica Clínica Idioma: Español Revista: Nucleus (La Habana) Asunto de la revista: Medicina Nuclear / Radioterapia Año: 2017 Tipo del documento: Artículo País de afiliación: Cuba Institución/País de afiliación: Centro de Isótopos/CU

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Tipo de estudio: Guía de Práctica Clínica Idioma: Español Revista: Nucleus (La Habana) Asunto de la revista: Medicina Nuclear / Radioterapia Año: 2017 Tipo del documento: Artículo País de afiliación: Cuba Institución/País de afiliación: Centro de Isótopos/CU