Linearidade e carryover do contador hematológico Horiba ® Abx Micros ESV 60 / Linearity and carryover of automated hematology counter Horiba ® Abx Micros ESV 60
Pesqui. vet. bras
; Pesqui. vet. bras;38(2): 345-349, fev. 2018. tab, graf
Article
en Pt
| LILACS, VETINDEX
| ID: biblio-895580
Biblioteca responsable:
BR68.1
RESUMO
O contador automático hematológico ABX Micros ESX 60 (Horiba Medical 2012) é analisador hematológico veterinário multi-espécie que realiza 50 contagens por hora, libera 18 parâmetros sanguíneos, além de fazer representações gráficas (histogramas) para leucócitos, hemácias e plaquetas. O objetivo deste trabalho é avaliar o desempenho do referido aparelho em relação à linearidade e carryover, através de controle comercial e de amostras de sangue provenientes da rotina do Laboratório de Patologia Clínica Veterinária. De acordo com resultados é possível afirmar que o presente aparelho possui um excelente coeficiente de linearidade (r2=0,99) nos parâmetros de leucócitos, eritrócitos e plaquetas em relação às diluições estudadas. Em relação aos carryover houve excelente desempenho do aparelho, contudo, houve valores não conformes nos parâmetros de CHCM e VPM em uma das metodologias realizadas que pode ser justificada pela limitação da fórmula que não considera a características do equipamento.(AU)
ABSTRACT
The automated hematology counter ABX Micros 60 ESX (Horiba Medical 2012) is veterinary hematology analyzer multi-species that carries 50 counts per hour releases 18 blood parameters, in addition to graphical representations (histograms) for leukocytes, erythrocytes and platelets. The objective of this study is to evaluate the performance of the apparatus with respect to linearity and carryover through commercial control and blood samples from the routine of Veterinary Clinical Pathology Laboratory. According to results we can say that this device has excellent linearity coefficient (r2=0.99) in leukocyte parameters, erythrocytes and platelets during that time dilutions. Regarding the carryover was excellent device performance, however, was not in conformity values ââin the parameters of MCHC and VPM in one of the methodologies made that can be justified by the limited formula that does not consider the equipment characteristics.(AU)
Palabras clave
Texto completo:
1
Índice:
LILACS
Asunto principal:
Recuento de Plaquetas
/
Recuento de Eritrocitos
/
Pruebas Hematológicas
/
Recuento de Leucocitos
Idioma:
Pt
Revista:
Pesqui. vet. bras
Asunto de la revista:
MEDICINA VETERINARIA
Año:
2018
Tipo del documento:
Article