Your browser doesn't support javascript.
loading
Subcutaneous implantable cardioverter defibrillator: early experience
Souza, Fernando Sérgio Oliva; Matos, Vanessa Sepulvida; Almeida, Marcos Cesar Valério; Weiss, Samuel Campagiotto; Rodrigues, Lucas Henrique Borges; Lima, Pedro Augusto Gori; Mattos, Davi Bongiolo.
  • Souza, Fernando Sérgio Oliva; Instituto de Arritmias Cardíacas (IAC). São Paulo. BR
  • Matos, Vanessa Sepulvida; Instituto de Arritmias Cardíacas (IAC). São Paulo. BR
  • Almeida, Marcos Cesar Valério; Instituto de Arritmias Cardíacas (IAC). São Paulo. BR
  • Weiss, Samuel Campagiotto; Instituto de Arritmias Cardíacas (IAC). São Paulo. BR
  • Rodrigues, Lucas Henrique Borges; Instituto de Arritmias Cardíacas (IAC). São Paulo. BR
  • Lima, Pedro Augusto Gori; Instituto de Arritmias Cardíacas (IAC). São Paulo. BR
  • Mattos, Davi Bongiolo; Instituto de Arritmias Cardíacas (IAC). São Paulo. BR
Rev. bras. cir. cardiovasc ; 32(6): 498-502, Nov.-Dec. 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-897968
ABSTRACT
Abstract

Introduction:

The implantable cardioverter defibrillator had been increasing the survival of patients at high risk for sudden cardiac death. The subcutaneous implantable cardioverter defibrillator was developed to mitigate the complications inherent to lead placement into cardiovascular system.

Objective:

To report the initial experience of 18 consecutive cases of subcutaneous implantable cardioverter defibrillator implantation showing the indications, potential pitfalls and perioperative complications.

Methods:

Between September 2016 and March 2017, 18 patients with indication for primary and secondary prevention of sudden cardiac death, with no concomitant indication for artificial cardiac pacing, were included.

Results:

The implantation of the subcutaneous implantable cardioverter defibrillator successfully performed in 18 patients. It was difficult to place the subcutaneous lead at the parasternal line in two patients. One patient returned a week after the procedure complaining about an increase in pain intensity at pulse generator pocket site, which was associated with edema, temperature rising and hyperemia. Two patients took antialgic medication for five days after surgery. A reintervention was necessary in one patient to replace the lead in order to correct inappropriate shocks caused by myopotential oversensing.

Conclusion:

In our initial experience, although the subcutaneous implantable cardioverter defibrillator implantation is a less-invasive, simple-accomplishment procedure, it resulted in a bloodier surgery perhaps requiring an operative care different from the conventional. Inappropriate shock by oversensing is a reality in this system, which should be overcame in order not to become a limiting issue for its indication.
Asunto(s)


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Fibrilación Ventricular / Cardioversión Eléctrica / Estimulación Cardíaca Artificial / Muerte Súbita Cardíaca / Desfibriladores Implantables / Prevención Secundaria Tipo de estudio: Estudio de etiología Límite: Femenino / Humanos / Masculino Idioma: Inglés Revista: Rev. bras. cir. cardiovasc Asunto de la revista: Cardiología / Cirugía General Año: 2017 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Instituto de Arritmias Cardíacas (IAC)/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Fibrilación Ventricular / Cardioversión Eléctrica / Estimulación Cardíaca Artificial / Muerte Súbita Cardíaca / Desfibriladores Implantables / Prevención Secundaria Tipo de estudio: Estudio de etiología Límite: Femenino / Humanos / Masculino Idioma: Inglés Revista: Rev. bras. cir. cardiovasc Asunto de la revista: Cardiología / Cirugía General Año: 2017 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Instituto de Arritmias Cardíacas (IAC)/BR