Your browser doesn't support javascript.
loading
Transcatheter aortic valve replacement: the experience of one brazilian health care center
Azevedo, Fabiula Schwartz; Correa, Marcelo Goulart; Paula, Débora Holanda Gonçalves; Felix, Alex dos Santos; Belém, Luciano Herman Juaçaba; Mendes, Ana Paula Chedid; Silva, Valeria Gonçalves; Marques, Bruno Miranda; Monteiro, Andrey José de Oliveira; Weksler, Clara; Colafranceschi, Alexandre Siciliano; Kasal, Daniel Arthur Barata.
  • Azevedo, Fabiula Schwartz; Instituto Nacional de Cardiologia. Rio de Janeiro. BR
  • Correa, Marcelo Goulart; Instituto Nacional de Cardiologia. Rio de Janeiro. BR
  • Paula, Débora Holanda Gonçalves; Instituto Nacional de Cardiologia. Rio de Janeiro. BR
  • Felix, Alex dos Santos; Instituto Nacional de Cardiologia. Rio de Janeiro. BR
  • Belém, Luciano Herman Juaçaba; Instituto Nacional de Cardiologia. Rio de Janeiro. BR
  • Mendes, Ana Paula Chedid; Instituto Nacional de Cardiologia. Rio de Janeiro. BR
  • Silva, Valeria Gonçalves; Instituto Nacional de Cardiologia. Rio de Janeiro. BR
  • Marques, Bruno Miranda; Instituto Nacional de Cardiologia. Rio de Janeiro. BR
  • Monteiro, Andrey José de Oliveira; Instituto Nacional de Cardiologia. Rio de Janeiro. BR
  • Weksler, Clara; Instituto Nacional de Cardiologia. Rio de Janeiro. BR
  • Colafranceschi, Alexandre Siciliano; Instituto Nacional de Cardiologia. Rio de Janeiro. BR
  • Kasal, Daniel Arthur Barata; Instituto Nacional de Cardiologia. Rio de Janeiro. BR
Rev. bras. cir. cardiovasc ; 33(1): 1-7, Jan.-Feb. 2018. tab, graf
Artículo en Inglés | LILACS | ID: biblio-897979
ABSTRACT
Abstract

Objective:

Transcatheter aortic valve replacement has been an alternative to invasive treatment for symptomatic severe aortic stenosis in high risk patients. The primary endpoint was 30-day and 1-year mortality from any cause. Secondary endpoints were to compare the clinical and echocardiographic variation pre-and post- transcatheter aortic valve replacement, and the occurrence of complications throughout a 4-year follow-up period.

Methods:

This prospective cohort, nestled to a multicenter study (Registro Brasileiro de Implante de Bioprótese por Cateter), describes the experience of a public tertiary center in transcatheter aortic valve replacement. All patients who underwent this procedure between October 2011 and February 2016 were included.

Results:

Fifty-eight patients underwent transcatheter aortic valve replacement. The 30-day all-cause mortality was 5.2% (n=3) and after 1 year was 17.2% (n=10). A significant improvement in New York Heart Association functional classification was observed when comparing pre-and post- transcatheter aortic valve replacement (III or IV 84.4% versus 5.8%; P<0.001). A decline in peak was observed (P<0.001) and mean (P<0.001) systolic transaortic gradient. The results of peak and mean post-implant transaortic gradient were sustained after one year (P=0.29 and P=0.36, respectively). Left ventricular ejection fraction did not change significantly during follow-up (P=0.41). The most frequent complications were bleeding (28.9%), the need for permanent pacemaker (27.6%) and acute renal injury (20.6%).

Conclusion:

Mortality and complications in this study were consistent with worldwide experience. Transcatheter aortic valve replacement had positive clinical and hemodynamic results, when comparing pre-and post-procedure, and the hemodynamic profile of the prosthesis was sustained throughout follow-up.
Asunto(s)


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Estenosis de la Válvula Aórtica / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Ensayo Clínico Controlado / Estudio de etiología / Estudio observacional / Factores de riesgo Límite: Anciano / Aged80 / Femenino / Humanos / Masculino País/Región como asunto: America del Sur / Brasil Idioma: Inglés Revista: Rev. bras. cir. cardiovasc Asunto de la revista: Cardiología / Cirugía General Año: 2018 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Instituto Nacional de Cardiologia/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Estenosis de la Válvula Aórtica / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Ensayo Clínico Controlado / Estudio de etiología / Estudio observacional / Factores de riesgo Límite: Anciano / Aged80 / Femenino / Humanos / Masculino País/Región como asunto: America del Sur / Brasil Idioma: Inglés Revista: Rev. bras. cir. cardiovasc Asunto de la revista: Cardiología / Cirugía General Año: 2018 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Instituto Nacional de Cardiologia/BR