Your browser doesn't support javascript.
loading
Resultados visuales de implante de lente trifocal en pacientes con glaucoma / Visual outcomes with trifocal lens implant in glaucoma patients
Garcés Valencia, Angela María; Escalante Castañón, Mariana; Meissner, Daniela; Castañeda Diez, Rafael; Jiménez Román, Jesús.
  • Garcés Valencia, Angela María; Servicio de glaucoma. Asociación para evitar la ceguera en México. Hospital Dr. Luis Sánchez Bulnes. México. MX
  • Escalante Castañón, Mariana; Servicio de glaucoma. Asociación para evitar la ceguera en México. Hospital Dr. Luis Sánchez Bulnes. México. MX
  • Meissner, Daniela; Servicio de glaucoma. Asociación para evitar la ceguera en México. Hospital Dr. Luis Sánchez Bulnes. México. MX
  • Castañeda Diez, Rafael; Servicio de glaucoma. Asociación para evitar la ceguera en México. Hospital Dr. Luis Sánchez Bulnes. México. MX
  • Jiménez Román, Jesús; Servicio de glaucoma. Asociación para evitar la ceguera en México. Hospital Dr. Luis Sánchez Bulnes. México. MX
Rev. Soc. Colomb. Oftalmol ; 49(4): 280-287, 2016. tab. graf.
Artículo en Español | LILACS, COLNAL | ID: biblio-905179
RESUMEN

Objetivo:

Evaluar los resultados visuales en pacientes con sospecha de glaucoma y glaucoma leve candidatos a cirugía de catarata e implante de lente intraocular trifocal. Diseño del estudio Estudio longitudinal, prospectivo, experimental y analítico.

Métodos:

Se incluyeron pacientes con catarata y diagnóstico de glaucoma leve o sospechoso de glaucoma que contaran con campo visual, tomografía de nervio óptico y estudio de sensibilidad al contraste y se les realizo cirugía de catarata por facoemulsificación del cristalino con implante de lente intraocular trifocal AT LISA tri 839 MP.

Resultados:

Se incluyeron 9 ojos de 5 pacientes (4 mujeres y 1 hombre) entre los 66 y 87 años con un promedio de 73.2 ± 7.6 años. La agudeza visual prequirúrgica con corrección lejana fue de 0.29±0.16 LogMar (20/40), intermedia 0.67±0.49 LogMar (20/60), cercana 0.66± 0.57 LogMar (20/80); al mes postquirúrgico la agudeza visual con corrección lejana fue 0.08± 0.06 LogMar (20/25), intermedia 0.05± 0.06 LogMar (20/20), cercana 0.02±0.03 LogMar (20/20). Encontramos una mejoría estadísticamente significativa de la agudeza visual al mes de postoperatorio. En el análisis de la sensibilidad al contraste prequirúrgica y postquirúrgica, no observamos diferencias estadísticamente significativas en ninguna de las frecuencias espaciales (3cpg 1.32 ± 0.25 vs 1.34 ± 0.26, 6cpg 1.41 ± 0.30 vs 1.46 ± 0.28, 12 cpg 1.094 ± 0.42 vs 0.98 ± 0.37, 18cpg 0.69 ± 0.41 vs 0.60 ± 0.30).

Conclusiones:

Los resultados visuales obtenidos a diferentes distancias con el diseño trifocal indican que esta técnica emergente constituye una alternativa para la cirugía de catarata para pacientes candidatos con glaucoma leve o sospecha de glaucoma sin que el procedimiento altere su seguimiento ni modifique la sensibilidad al contraste.
ABSTRACT

Objective:

To evaluate visual results in patients with glaucoma suspect and mild glaucoma, candidates for cataract surgery and trifocal intraocular lens implantation. Study

design:

Longitudinal, prospective, experimental and analytical study.

Methods:

We include patients with cataract and diagnosis of mild or glaucoma suspect who had a visual field, optic nerve tomography and contrast sensitivity study. They underwent to cataract surgery with trifocal intraocular lens implant (ATLISAtri839MP).

Results:

9 eyes of 5 patients (4 women and 1 man) were included between 66 and 87 years, with an average of 73.2 ± 7.6 years. Preoperative visual acuity with distance correction was 0.29 ± 0.16 LogMar (20/40), intermediate 0.67 ± 0.49 LogMar (20/60), near to 0.66 ± 0.57 LogMar (20/80); the results per month were the visual acuity with distance correction was 0.08 ± 0.06 LogMar (20/25), intermediate 0.05 ± 0.06 LogMar (20/20), near to 0.02 ± 0.03 LogMar (20/20). We found improvement in visual acuity at the month of postoperative, statistically significant. In the analysis of preoperative and postsurgical contrast sensitivity, we did not observe statistically signifi cant differences in any of the spatial frequencies (3cpg 1.32 ± 0.25 vs 1.34 ± 0.26, 6cpg 1.41 ± 0.30 vs 1.46 ± 0.28, 12 cpg 1.094 ± 0.42 vs 0.98 ± 0.37, 18 cpg 0.69 ± 0.41 vs. 0.60 ± 0.30).

Conclusions:

The visual results obtained at different distances with the trifocal design indicate that this emerging technique is an alternative for cataract surgery for candidates with mild glaucoma or glaucoma suspect; whereas the procedure does not alter follow-up or contrast sensitivity.
Asunto(s)

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Implantación de Lentes Intraoculares Tipo de estudio: Estudio observacional Idioma: Español Revista: Rev. Soc. Colomb. Oftalmol Asunto de la revista: Oftalmología Año: 2016 Tipo del documento: Artículo País de afiliación: México Institución/País de afiliación: Servicio de glaucoma. Asociación para evitar la ceguera en México. Hospital Dr. Luis Sánchez Bulnes/MX

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Implantación de Lentes Intraoculares Tipo de estudio: Estudio observacional Idioma: Español Revista: Rev. Soc. Colomb. Oftalmol Asunto de la revista: Oftalmología Año: 2016 Tipo del documento: Artículo País de afiliación: México Institución/País de afiliación: Servicio de glaucoma. Asociación para evitar la ceguera en México. Hospital Dr. Luis Sánchez Bulnes/MX