Terapia de resincronización cardíaca: un paciente con extrema disfunción ventricular y múltiples comorbilidades / Cardiac resynchronization therapy: a patient with extreme ventricular dysfunction and multiple comorbidities
Villarroel Ábrego, Hugo; Núñez, Elaine; Garillo, Raúl.
Afiliación
  • Villarroel Ábrego, Hugo; Universidad Salvadoreña Alberto Masferrer. Facultad de Medicina. San Salvador. SV
  • Núñez, Elaine; Centros de Diagnóstico y Medicina Avanzada y de Conferencias Médicas y Telemedicina. Santo Domingo. DO
  • Garillo, Raúl; Pontificia Universidad Católica Argentina. Facultad de Ciencias Médicas. Buenos Aires. AR
Rev. costarric. cardiol ; 20(1): 42-48, ene.-jun. 2018.
Article en Es | LILACS | ID: biblio-960267
Biblioteca responsable: CR1.1
RESUMEN
Resumen Se presenta el caso de un varón de 56 años con cardiomiopatía no compactada y muy severa disfunción ventricular, con trastorno de conducción intraventricular y QRS ancho. Adolecía de comorbilidades incluyendo nefropatía diabética termi nal (en diálisis) y nunca pudo recibir terapia médica óptima por hipotensión e hiperkalemia. Con indicación IIa para terapia de resincronización cardíaca se le implantó resincronizador con desfibrilador, con respuesta aguda clínica y ecocardiográ fica excelente. Falleció a los tres meses del implante por asistolia que no pudo ser rescatada por el dispositivo. Es nuestra opinión que la presencia de comorbilidades graves y la imposibilidad de dar terapia médica óptima son una limitante para el éxito a mediano y largo plazo de la terapia de resincronización.
ABSTRACT
Abstract We present the case of a 56-year-old man with non-compaction cardiomyopathy and very severe ventricular dysfunction, with intraventricular conduction disorder and wide QRS. He suffered from comorbidities including terminal diabetic nephropathy (on dialysis) and was never able to receive optimal medical therapy for hypotension and hyperkalemia. With indication IIa for cardiac resynchronization therapy, a resynchronizer with a defibrillator was implanted, with an acute clinical and excellent echocardiographic response. He died three months after the implant due to asystole that could not be rescued by the device. It is our opinion that the presence of severe comorbidities and the impossibility of giving optimal medical therapy are a limitation for the medium and long-term success of the resynchronization therapy.
Asunto(s)
Palabras clave
Texto completo: 1 Índice: LILACS Asunto principal: Comorbilidad / Disfunción Ventricular / No Compactación Aislada del Miocardio Ventricular / Terapia de Resincronización Cardíaca / Cardiomiopatías Límite: Humans / Male Idioma: Es Revista: Rev. costarric. cardiol Asunto de la revista: CARDIOLOGIA Año: 2018 Tipo del documento: Article
Texto completo: 1 Índice: LILACS Asunto principal: Comorbilidad / Disfunción Ventricular / No Compactación Aislada del Miocardio Ventricular / Terapia de Resincronización Cardíaca / Cardiomiopatías Límite: Humans / Male Idioma: Es Revista: Rev. costarric. cardiol Asunto de la revista: CARDIOLOGIA Año: 2018 Tipo del documento: Article