Confiabilidad de un monitor automatizado para la medición de la presión arterial / Reliability of an automatic monitor for blood pressure measurement
Cardona-Müller, David; Grover-Páez, Fernando; Guzmán-Saldivar, Víctor; Alanis-Sánchez, Guillermo A; Murguía-Soto, César; Totsuka-Sutto, Sylvia E; Quezada-Fernández, Patricia; Macías-Chumacera, Agustín; Cardona-Muñoz, Ernesto G; Ramos-Becerra, Carlos G.
  • Cardona-Müller, David; Universidad de Guadalajara. Departamento de Fisiología del Centro Universitario de Ciencias de la Salud. Instituto de Terapéutica Experimental y Clínica. Guadalajara. MX
  • Grover-Páez, Fernando; Universidad de Guadalajara. Departamento de Fisiología del Centro Universitario de Ciencias de la Salud. Instituto de Terapéutica Experimental y Clínica. Guadalajara. MX
  • Guzmán-Saldivar, Víctor; Universidad de Guadalajara. Departamento de Fisiología del Centro Universitario de Ciencias de la Salud. Instituto de Terapéutica Experimental y Clínica. Guadalajara. MX
  • Alanis-Sánchez, Guillermo A; Universidad de Guadalajara. Departamento de Fisiología del Centro Universitario de Ciencias de la Salud. Instituto de Terapéutica Experimental y Clínica. Guadalajara. MX
  • Murguía-Soto, César; Universidad de Guadalajara. Departamento de Fisiología del Centro Universitario de Ciencias de la Salud. Instituto de Terapéutica Experimental y Clínica. Guadalajara. MX
  • Totsuka-Sutto, Sylvia E; Universidad de Guadalajara. Departamento de Fisiología del Centro Universitario de Ciencias de la Salud. Instituto de Terapéutica Experimental y Clínica. Guadalajara. MX
  • Quezada-Fernández, Patricia; Universidad de Guadalajara. Departamento de Fisiología del Centro Universitario de Ciencias de la Salud. Instituto de Terapéutica Experimental y Clínica. Guadalajara. MX
  • Macías-Chumacera, Agustín; Universidad de Guadalajara. Departamento de Fisiología del Centro Universitario de Ciencias de la Salud. Instituto de Terapéutica Experimental y Clínica. Guadalajara. MX
  • Cardona-Muñoz, Ernesto G; Universidad de Guadalajara. Departamento de Fisiología del Centro Universitario de Ciencias de la Salud. Instituto de Terapéutica Experimental y Clínica. Guadalajara. MX
  • Ramos-Becerra, Carlos G; Universidad de Guadalajara. Departamento de Fisiología del Centro Universitario de Ciencias de la Salud. Instituto de Terapéutica Experimental y Clínica. Guadalajara. MX
Rev. méd. Chile ; 146(2): 190-195, feb. 2018. tab, graf
Artículo en Español | LILACS | ID: biblio-961377
ABSTRACT
Background A correct blood pressure (BP) measurement is essential for the diagnosis and control of high BP. Aim: To evaluate the agreement and repeatability of BP measurements with the OMRON HEM-7320-LA device compared to a mercury sphygmomanometer. Material and Methods: A cross-sectional study comparing BP measurements made by two randomly selected trained nurses and an automatic oscillometric device. The mercurial sphygmomanometer was connected to the automated device via a "T" type connector and a dual-head stethoscope was used, allowing simultaneous measurements. The results were analyzed with one-factor analysis of variance, Bland-Altman's test, repeatability coefficient (RC), and intra-class correlation coefficient (ICC). Results: Forty-nine participants aged 56 ± 19 years were included. Nineteen had hypertension (38%). We did not observe a significant difference in either systolic (SBP) or diastolic blood pressure (DBP) pressure measurements between the observers and the device. The mean difference was −0.09 mmHg (95% confidence intervals (CI)-0.9 to 0.7) for SBP and −0.9 mmHg (95% CI −1.7 to −0.13) for DBP. The RC for SBP (6.2, 5.2 and 5.8 mmHg) and DBP (4.7, 4.2 y 5.2 mmHg) was similar between the observers and the device. The ICC for SBP was 0.990 (95% CI 0.983 to 0.995, p < 0.01) and 0.986 (95% CI 0.977 to 0.991, p < 0.01) for DBP. Conclusions: There was a high level of agreement and similar measurement repeatability in the measurements performed by the automatic device and the mercurial sphygmomanometer. No differences in BP measurements were observed.
Asunto(s)


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Determinación de la Presión Sanguínea / Monitores de Presión Sanguínea / Hipertensión Tipo de estudio: Estudio observacional / Estudio de prevalencia / Factores de riesgo Límite: Femenino / Humanos / Masculino Idioma: Español Revista: Rev. méd. Chile Asunto de la revista: Medicina Año: 2018 Tipo del documento: Artículo País de afiliación: México Institución/País de afiliación: Universidad de Guadalajara/MX

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Determinación de la Presión Sanguínea / Monitores de Presión Sanguínea / Hipertensión Tipo de estudio: Estudio observacional / Estudio de prevalencia / Factores de riesgo Límite: Femenino / Humanos / Masculino Idioma: Español Revista: Rev. méd. Chile Asunto de la revista: Medicina Año: 2018 Tipo del documento: Artículo País de afiliación: México Institución/País de afiliación: Universidad de Guadalajara/MX