Your browser doesn't support javascript.
loading
Confiabilidad interevaluador de la prueba video head impulse test en estudiantes de primer año de la generación 2016 de la Escuela de Fonoaudiología de la Universidad de Valparaíso Casa Central / Inter-rater reliability of the video head impulse test in students from the School of Speech and Language therapist of the University of Valparaiso main campus class 2016
Gómez L, Andre; Álvarez N, Valeria; López R, Allison; Neira M, Rodrigo.
  • Gómez L, Andre; Universidad de Valparaíso. Facultad de Medicina. Escuela de Fonoaudiología Casa Central. Viña del Mar. CL
  • Álvarez N, Valeria; Universidad de Valparaíso. CL
  • López R, Allison; Universidad de Valparaíso. CL
  • Neira M, Rodrigo; Universidad de Valparaíso. CL
Rev. otorrinolaringol. cir. cabeza cuello ; 78(3): 267-274, set. 2018. tab, graf
Artículo en Español | LILACS | ID: biblio-978811
RESUMEN
RESUMEN

Introducción:

El video head impulse test es un método rápido, no invasivo y cómodo para evaluar el reflejo vestíbulo ocular, el cual está siendo utilizado con mayor frecuencia en la evaluación de pacientes con alteraciones del equilibrio. Sin embargo, en Chile se evidencia una falta de estudios relacionados a la confiabilidad interevaluador de dicha prueba.

Objetivo:

Determinar el nivel de concordancia de los resultados de la eficiencia del reflejo vestíbulo ocular de los canales semicirculares horizontales, obtenidos mediante la aplicación de la prueba video head impulse test, por parte de 3 evaluadores. Material y

método:

Estudio cuantitativo, correlacional, no experimental transversal descriptivo, con muestreo no probabilístico, de participación voluntaria. La prueba video head impulse test fue aplicada por 3 examinadores a 30 estudiantes que cumplieron con los criterios de inclusión.

Resultados:

El método de Bland y Altman mostró gran concordancia en las mediciones realizadas entre los 3 examinadores. La correlación intraclase para la ganancia del canal semicircular horizontal derecho e izquierdo fue de 0,85 y 0,91 respectivamente y de 0,75 para el valor de asimetría.

Conclusión:

El estudio mostró una confiabilidad interevaluador adecuada de la prueba video head impulse test para la evaluación de los canales semicirculares horizontales.
ABSTRACT
ABSTRACT

Introduction:

The video head impulse test is a rapid, non-invasive and comfortable method for the evaluation of the vestibulo-ocular reflex that is being used more often in the evaluation of patients with balance disorders. In Chile there is a lack of studies related to the inter-rater reliability for this test.

Aim:

To determine the level of agreement on the results for the vestibulo-ocular reflex of the horizontal semicircular canals obtained by the execution of the video head impulse test by 3 raters. Material and

method:

Quantitative, correlational, non-experimental, cross-sectional descriptive study with a type of non-probability sampling with voluntary participation. The video head impulse test was applied by 3 raters to 30 students who fulfilled the inclusion criteria.

Results:

The Bland-Altman method demonstrated good agreement in the measurements made between the 3 raters. The inter-rater reliability for the gain of the left and right horizontal semicircular canals was 0.85 and 0.91 respectively and 0.75 for the asymmetry value.

Conclusion:

The study showed an adequate inter-rater reliability for the video head impulse test in the evaluation of the horizontal semicircular canals.
Asunto(s)


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Reflejo Vestibuloocular / Prueba de Impulso Cefálico Tipo de estudio: Estudio diagnóstico / Estudios de evaluación Límite: Adolescente / Adulto / Femenino / Humanos / Masculino País/Región como asunto: America del Sur / Chile Idioma: Español Revista: Rev. otorrinolaringol. cir. cabeza cuello Asunto de la revista: Otorrinolaringologia Año: 2018 Tipo del documento: Artículo País de afiliación: Chile Institución/País de afiliación: Universidad de Valparaíso/CL

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Reflejo Vestibuloocular / Prueba de Impulso Cefálico Tipo de estudio: Estudio diagnóstico / Estudios de evaluación Límite: Adolescente / Adulto / Femenino / Humanos / Masculino País/Región como asunto: America del Sur / Chile Idioma: Español Revista: Rev. otorrinolaringol. cir. cabeza cuello Asunto de la revista: Otorrinolaringologia Año: 2018 Tipo del documento: Artículo País de afiliación: Chile Institución/País de afiliación: Universidad de Valparaíso/CL