Contaminação microbiana em colírios de pacientes em tratamento de glaucoma / Microbial contamination in eye drops of patients in glaucoma treatment
Figuêiredo, Lucas Vianna; Mantovani, Charles Maroly Lessa; Vianna, Mariella Saponara; Fonseca, Bárbara Miorim; Costa, Ana Amélia Abib Nogueira; Mesquita, Yara Baldin; Polveiro, Jullyana Pitaluga de Souza Castro; Nassaralla Júnior, João J.
  • Figuêiredo, Lucas Vianna; Santa Casa de Misericórdia. Programa de Residência em Oftalmologia. Ribeirão Preto. BR
  • Mantovani, Charles Maroly Lessa; Centro Universitário Barão de Mauá. Curso Acadêmico de Medicina. Ribeirão Preto. BR
  • Vianna, Mariella Saponara; Saúde Instituto de Análises Clínicas. Goiânia. BR
  • Fonseca, Bárbara Miorim; Santa Casa de Misericórdia. Programa de Residência em Oftalmologia. Ribeirão Preto. BR
  • Costa, Ana Amélia Abib Nogueira; Santa Casa de Misericórdia. Programa de Residência em Oftalmologia. Ribeirão Preto. BR
  • Mesquita, Yara Baldin; Santa Casa de Misericórdia. Programa de Residência em Oftalmologia. Ribeirão Preto. BR
  • Polveiro, Jullyana Pitaluga de Souza Castro; Saúde Instituto de Análises Clínicas. Goiânia. BR
  • Nassaralla Júnior, João J; Instituto de Olhos de Goiânia. Departamento de Retina e Vítreo. Goiânia. BR
Rev. bras. oftalmol ; 77(6): 320-323, nov.-dez. 2018. graf
Artículo en Portugués | LILACS | ID: biblio-985314
RESUMO
Resumo

Objetivos:

Avaliar o grau de contaminação por fungos e bactérias e o modo de conservação destes colírios hipotensores por parte dos pacientes no ambulatório de Glaucoma da Santa Casa de Ribeirão Preto.

Métodos:

Foram selecionados aleatoriamente cinquenta e cinco pacientes, em seguimento no ambulatório, e após consentimento dos mesmos os colírios eram coletados e enviados via correio para análise por microbiologista e patologista em até 72 horas. Foi analisado 0,5ml aproximadamente das medicações e os pacientes respondiam a um questionário simples sobre o método de conservação e se consideravam estes adequados.

Resultados:

Dos 55 colírios analisados, cinco (9,01%) estavam com seu conteúdo líquido contaminado. Entre os microrganismos isolados haviam 4 bactérias Gram negativas, sendo 1 (1,8%) por Serratia marcescens, 1 (1,8%) Pseudomonas aeruginosa e 2 (3,6%) Stenotrophomas maltophilia. Um colírio estava contaminado pelo fungo Cândida ssp Todos pacientes do estudo julgam seus métodos de armazenamento e instilação adequados. Os pacientes que tiveram os colírios positivados eram convocados para exame clínico e passavam por novo questionário pelo investigador.

Conclusão:

O tempo de abertura dos frascos e os métodos de conservação influenciam na contaminação dos medicamentos, todos os colírios com crescimento de microrganismos no presente estudo estavam abertos entre 30 e 90 dias. O fato de que a maioria dos pacientes levam seus colírios em tarefas cotidianas, aumenta a exposição dos frascos e podem ser um fator relevante para determinar a contaminação destas medicações.
ABSTRACT
Abstract Objetives To assess the degree of fungal and bacterial contamination of hypotensive eye drops and the way these are preserved by the patients at the Glaucoma outpatient clinic of Santa Casa Hospital in Ribeirão Preto.

Methods:

Fifty-five patients were randomly assigned to follow-up in the outpatient clinic and, after their consent, an eye drop was collected per patient and later sent by mail for analysis by microbiologist and pathologist in up to 72 hours. Approximately 0.5ml of the medications were analyzed and the patients were asked to answer a simple questionnaire on the method of drug conservation and whether they considered it adequate.

Results:

Of the 55 analysed eye drops, five (9.01%) had their liquid contents contaminated. Among the microorganisms isolated there were 4 Gram negative bacteria, 1 (1.8%) by Serratia marcenses, 1 (1.8%) Pseudomonas aeruginosa and 2 (3.6%) Stenotrophomas maltophilia. An eye drop was contaminated by the fungus Candida ssp. All the patients in the study judged their methods of storage and instillation appropriate. The patients who had the positive coliria were summoned for clinical examination and passed through a new questionnaire by the investigator.

Conclusion:

The time and methods of preservation influence the contamination of medicinal products. All the eye drops that presented growth of microorganisms in the present study were open between 30 and 90 days. The fact that most patients take their eye drops on daily tasks increases the exposure of the bottles and can be a relevant fact to determine the contamination of these medications.
Asunto(s)


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Soluciones Oftálmicas / Glaucoma / Contaminación de Medicamentos Tipo de estudio: Ensayo Clínico Controlado / Estudio observacional / Estudio de prevalencia / Factores de riesgo Límite: Anciano / Femenino / Humanos / Masculino Idioma: Portugués Revista: Rev. bras. oftalmol Asunto de la revista: Oftalmología Año: 2018 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Centro Universitário Barão de Mauá/BR / Instituto de Olhos de Goiânia/BR / Santa Casa de Misericórdia/BR / Saúde Instituto de Análises Clínicas/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Soluciones Oftálmicas / Glaucoma / Contaminación de Medicamentos Tipo de estudio: Ensayo Clínico Controlado / Estudio observacional / Estudio de prevalencia / Factores de riesgo Límite: Anciano / Femenino / Humanos / Masculino Idioma: Portugués Revista: Rev. bras. oftalmol Asunto de la revista: Oftalmología Año: 2018 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Centro Universitário Barão de Mauá/BR / Instituto de Olhos de Goiânia/BR / Santa Casa de Misericórdia/BR / Saúde Instituto de Análises Clínicas/BR