ABSTRACT
We report a case of unexpected kinking of endotracheal [ET] tube in an infant who was being operated in supine position and positioned away from the anesthetist. The usual management mentioned in the literature was unsuccessful. So, a simple and unique solution that can be useful in unanticipated kinking of ET tube is described
Asunto(s)
Buscar en Google
Índice: IMEMR (Mediterraneo Oriental) Asunto principal: Lactante / Anestesia / Anestesiología Tipo de estudio: Informe de Casos Límite: Humanos / Masculino Idioma: Inglés Revista: Saudi J. Anaesth. Año: 2013