SJA-Saudi Journal of Anaesthesia. 2013; 7 (3): 344-346
en Inglés
| IMEMR
| ID: emr-130464
ABSTRACT
We report a case of unexpected kinking of endotracheal [ET] tube in an infant who was being operated in supine position and positioned away from the anesthetist. The usual management mentioned in the literature was unsuccessful. So, a simple and unique solution that can be useful in unanticipated kinking of ET tube is described