Your browser doesn't support javascript.
loading
Minimal acceptable CPAP levels for tracheal extubation in newborn infants
Medical Journal of Cairo University [The]. 1990; 58 (4): 595-601
en Inglés | IMEMR | ID: emr-17362
ABSTRACT
The study showed that PaO2 [arterial oxygen tension] at 2 to 3 cm water [H2O] was nearly the same as observed following extubation, but was significantly lower at ZEEP; there was no significant change in PaCO2 [partial CO2 tension] or arterial pH when CPAP was discontinued or following extubation, hence tracheal extubation of newborn infants at the end of weaning of mechanical ventilation should be done at 2-3 cm H2O and not at ZEEP to prevent the reoccurrence of hypoxemia after extubation, this minimizing oxygen needs after extubation and preventing the hazards of high oxygen concentration
Asunto(s)
Buscar en Google
Índice: IMEMR (Mediterraneo Oriental) Asunto principal: Enfermedades de la Tráquea / Recién Nacido Idioma: Inglés Revista: Med. J. Cairo Univ. Año: 1990

Similares

MEDLINE

...
LILACS

LIS

Buscar en Google
Índice: IMEMR (Mediterraneo Oriental) Asunto principal: Enfermedades de la Tráquea / Recién Nacido Idioma: Inglés Revista: Med. J. Cairo Univ. Año: 1990