Your browser doesn't support javascript.
loading
Electron beam therapy shielding material and clinical applications
Journal of the Medical Research Institute-Alexandria University. 1996; 17 (3): 88-95
en Inglés | IMEMR | ID: emr-41293
ABSTRACT
The relative percent dose reduction of different electron energies [5, 9 and 13 Mev] were measured using Mevatron 74 Linear accelerator and different shielding materials [lead, aluminium, copper and stainless steel]. A step wedge of each was used during this wrk, the steps thickness ranged between 2 mm and 20 mm. It was found that 95% attenuation for energies [5, 9 and 13 Mev] were obtained by 2, 4 and 6 mm thickness of lead respectively compared to the attenuation obtained by other materials of the same tickness
Asunto(s)
Buscar en Google
Índice: IMEMR (Mediterraneo Oriental) Asunto principal: Radioterapia / Cobre / Aluminio / Dosimetría por Película / Plomo Idioma: Inglés Revista: J. Med. Res. Inst.-Alex. Univ. Año: 1996

Similares