Your browser doesn't support javascript.
loading
Comparison of the fluorescent polarization (TDx) and the enzymatic competitive (EMIT 2000) immune assays for the measurement of cyclosporin A blood concentration
David-Neto, Elias; Ballarati, Carlos A. F; Freitas, Orlando J; Lemos, Francine C; Nahas, William C; Arap, Sami; Kalil, Jorge.
  • David-Neto, Elias; Hospital Sírio Libanes. BR
  • Ballarati, Carlos A. F; Hospital Sírio Libanes. BR
  • Freitas, Orlando J; Hospital Sírio Libanes. BR
  • Lemos, Francine C; Hospital Sírio Libanes. BR
  • Nahas, William C; Hospital Sírio Libanes. BR
  • Arap, Sami; Hospital Sírio Libanes. BR
  • Kalil, Jorge; Hospital Sírio Libanes. BR
Rev. Hosp. Clin. Fac. Med. Univ. Säo Paulo ; 55(6): 207-212, Nov.-Dec. 2000. tab, graf
Artículo en Inglés | LILACS | ID: lil-283234
RESUMO
Evaluation of Cyclosporin A (CyA) blood concentration is imperative in solid organ transplantation in order to achieve maximal immunosuppression with the least side effects. We compared the results of whole blood concentrations of CyA in 50 blood samples simultaneously evaluated by the fluorescent polarization immune assay (TDx) and the enzymatic competitive immune assay (EMIT 2000). There was a strong correlation between both kits for any range of CyA blood concentration (R=0.99, p<0.001). The within-run and between-days coefficient of variation were less than 4 percent for both assays. The cost for each CyA measurement was 50 percent lower for the EMIT assay when compared to the TDx assay. We concluded that the EMIT is as accurate as the TDx in measuring CyA blood concentration and has the advantage of a lower cost, as well as the possibility of widespread access to the EMIT methodology in contrast to the TDx equipment, allowing the laboratory to perform several routines within a working day
Asunto(s)
Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Inmunoensayo de Polarización Fluorescente / Técnicas para Inmunoenzimas / Trasplante de Riñón / Ciclosporina Tipo de estudio: Evaluación Económica en Salud Límite: Humanos Idioma: Inglés Revista: Rev. Hosp. Clin. Fac. Med. Univ. Säo Paulo Asunto de la revista: Medicina Año: 2000 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Hospital Sírio Libanes/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Inmunoensayo de Polarización Fluorescente / Técnicas para Inmunoenzimas / Trasplante de Riñón / Ciclosporina Tipo de estudio: Evaluación Económica en Salud Límite: Humanos Idioma: Inglés Revista: Rev. Hosp. Clin. Fac. Med. Univ. Säo Paulo Asunto de la revista: Medicina Año: 2000 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Hospital Sírio Libanes/BR