Avaliação da exeqüibilidade, eficácia e segurança do transplante lamelar semi-automatizado de córnea / Evaluation of performance, efficacy and safety of semi-automated lamellar keratoplasty
Maia, Núbia Cristina de Freitas; Chamon, Wallace; Castelo Branco, Bruno.
  • Maia, Núbia Cristina de Freitas; Universidade Federal de São Paulo. São Paulo. BR
  • Chamon, Wallace; Universidade Federal de São Paulo. São Paulo. BR
  • Castelo Branco, Bruno; Universidade Federal de São Paulo. São Paulo. BR
Arq. bras. oftalmol ; 69(6): 795-804, nov.-dez. 2006. ilus, tab, graf
Artículo en Portugués | LILACS | ID: lil-440414
RESUMO
OBJETIVO: Avaliar a exeqüibilidade, eficácia e segurança do uso de microcerátomo e câmara anterior artificial para o transplante lamelar (sistema ALTK®). MÉTODOS: 21 olhos com opacidades corneanas superficiais foram submetidos ao transplante lamelar semi-automatizado de córnea. Nos olhos receptores a ceratectomia foi realizada de modo semelhante a uma cirurgia refrativa. As lamelas doadoras foram obtidas a partir de botões esclero-corneanos utilizando o mesmo microcerátomo e uma câmara anterior artificial. As medidas das espessuras corneanas foram feitas através da biomicroscopia ultra-sônica. RESULTADOS: As cirurgias obtiveram êxito em 19 olhos. Em 80 por cento das lamelas obtidas em córneas doadoras e em 84,2 por cento das lamelas em olhos receptores houve uma variação de até 0,5 mm do diâmetro desejado. Verificou-se alta semelhança entre as espessuras das lamelas obtidas nos olhos receptores e lamelas doadoras. Obteve-se acuidade visual corrigida pós-operatória igual ou superior a 20/40 em 52,6 por cento dos olhos. Foram observadas complicações como diâmetro inadequado da lamela, perfuração intra-operatória no olho receptor e ectasia corneana pós-operatória (um caso). CONCLUSÕES: O transplante lamelar semi-automatizado de córnea mostrou-se exequível pela reprodutibilidade das espessuras e diâmetros das lamelas; eficaz pela melhora da acuidade visual pós-operatória e seguro, devido ao baixo índice de complicações cirúrgicas.
ABSTRACT
PURPOSE: To evaluate the feasibility, efficacy and safety of a manual microkeratome and an artificial anterior chamber for lamellar keratoplasty (ALTK® system). METHODS: Twenty-one eyes with superficial corneal opacities were submitted to semi-automated lamellar keratectomy. In recipient eyes keratectomy was performed as in refractive surgery. The donor flap was removed from the preserved corneal shell using the same microkeratome and an artificial anterior chamber. Lamella thickness was measured through ultrasound biomicroscopy (UBM) after surgery. RESULTS: The surgeries were accomplished successfully in 19 eyes. 80 percent of the flaps obtained in donated corneas and 84.2 percent of the flaps in recipient eyes had an up to 0.5 mm variation variation of the desired diameter. A high similarity in flap thickness between the donor flap and the recipient cornea was obtained. Postoperative visual acuity of 20/40 or better was observed in 52.6 percent of the eyes. Complications such as undesired diameter of the flap, a case of perforation in the recipient eye and a case of cornea ectasia were observed. CONCLUSION: The semi-automated lamellar keratoplasty ALTK® system showed to be feasible due to the predictability and reproducibility regarding lamella thickness and diameter, efficient in the improvement of postoperative visual acuity and safe due to the low level surgical complication.
Asunto(s)

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Queratoplastia Penetrante / Opacidad de la Córnea / Sustancia Propia Tipo de estudio: Estudio de etiología / Estudio pronóstico Límite: Adolescente / Adulto / Femenino / Humanos / Masculino Idioma: Portugués Revista: Arq. bras. oftalmol Asunto de la revista: Oftalmología Año: 2006 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade Federal de São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Queratoplastia Penetrante / Opacidad de la Córnea / Sustancia Propia Tipo de estudio: Estudio de etiología / Estudio pronóstico Límite: Adolescente / Adulto / Femenino / Humanos / Masculino Idioma: Portugués Revista: Arq. bras. oftalmol Asunto de la revista: Oftalmología Año: 2006 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade Federal de São Paulo/BR