Your browser doesn't support javascript.
loading
Mudança do modo VVI para DDD ("upgrade") na troca eletiva do gerador de pulsos: análise comparativa clínico-funcional / Upgrading from VVI to DDD pacing Mode during elective replacement of pulse generator: a comparative clinical-functional analysis
Teno, Luiz Antonio Castilho; Costa, Roberto; Martinelli Filho, Martino; Castilho, Fabian Cecchi Teno; Ruiz, Ivan.
  • Teno, Luiz Antonio Castilho; Universidade de São Paulo. Faculdade de Medicina. Hospital das Clínicas. Instituto do Coração. São Paulo. BR
  • Costa, Roberto; Universidade de São Paulo. Faculdade de Medicina. Hospital das Clínicas. Instituto do Coração. São Paulo. BR
  • Martinelli Filho, Martino; Universidade de São Paulo. Faculdade de Medicina. Hospital das Clínicas. Instituto do Coração. São Paulo. BR
  • Castilho, Fabian Cecchi Teno; Universidade de São Paulo. Faculdade de Medicina. Hospital das Clínicas. Instituto do Coração. São Paulo. BR
  • Ruiz, Ivan; Universidade de São Paulo. Faculdade de Medicina. Hospital das Clínicas. Instituto do Coração. São Paulo. BR
Arq. bras. cardiol ; 88(2): 128-133, fev. 2007. tab, graf
Artículo en Portugués | LILACS | ID: lil-444351
RESUMO

OBJETIVO:

Comparar o comportamento clínico e funcional dos modos de estimulação ventricular e atrioventricular na troca eletiva do gerador de pulsos em pacientes com cardiopatia chagásica e bloqueio atrioventricular.

MÉTODOS:

Foram estudados comparativamente sob estimulação ventricular e atrioventricular 27 pacientes, inicialmente na inclusão do estudo e alternadamente no modo ventricular e atrioventricular em duas fases com duração de 90 dias, considerando o comportamento clínico, avaliado pela qualidade de vida e classe funcional, e o comportamento funcional, avaliado pela ecocardiografia transtorácica e pelo teste de caminhada de seis minutos. A análise estatística foi realizada na condição basal, modo ventricular e modo atrioventricular, utilizando-se o teste qui-quadrado e a análise de variância para medidas repetidas, considerando-se nível de significância de 0,05.

RESULTADOS:

A média das medidas avaliadas na qualidade de vida foram capacidade funcional (VVI 71,3+/-18,2 , DDD 69,3+/-20,4), estado geral (VVI 68,1+/-21,8 , DDD 69,4+/-19,4) e vitalidade (VVI 64,8+/-24,6 , DDD 67,6+/-25,5); na ecocardiografia FEVE (VVI 52,5+/-12,8 , DDD 51,8+/-14,9), DDFVE (VVI 53,0+/-7,7 , DDD 42,4+/-7,8), AE (VVI 38,6+/-5,4 DDD 38,5+/-5,1) e no teste de caminhada de seis minutos distância percorrida (VVI 463,4+/-84,7 , DDD 462,6+/-63,4). Houve quatro casos de complicações três associadas à mudança de modo de estimulação.

CONCLUSÃO:

Não houve diferença entre os dois modos de estimulação, no comportamento clínico, avaliado pela qualidade de vida e classe funcional e no comportamento funcional, avaliado pela ecocardiografia e pelo teste de caminhada de seis minutos.
ABSTRACT

OBJECTIVE:

Evaluate the clinical and functional behavior of the ventricular and atrioventricular stimulation modes in the elective replacement of pulse generator in patients with chagasic cardiopathy and atrioventricular block.

METHODS:

Twenty-seven patients under ventricular and atrioventricular stimulation were comparatively evaluated at the beginning of the study, and alternately in ventricular and atrioventricular modes in two 90-day phases, with regard to the clinical behavior evaluated according to quality of life and functional class, and the functional behavior evaluated by transthoracic echocardiography and the six-minute walk test. The statistical analysis was performed with patients at baseline, and under ventricular and atrioventricular modes, using the chi-square test and the repeated measures analysis of variance, and taking into consideration a 0.05 level of significance.

RESULTS:

The mean quality-of-life scores were functional capacity (VVI 71.3+/-18.2 , DDD 69.3+/-20.4); overall health status (VVI 68.1+/-21.8, DDD 69.4+/-19.4) and vitality (VVI 64.8+/-24.6 , DDD 67.6+/-25.5); on echocardiography LVEF (VVI 52.5+/-12.8 , DDD 51.8+/-14.9), LVDD (VVI 53.0+/-7.7 , DDD 42.4+/-7.8), LA (VVI 38.6+/-5.4 DDD 38.5+/-5.1), and in the six-minute walk test distance walked (VVI 463.4+/-84.7, DDD 462.6+/-63.4). There were four cases of complications, three of them associated with the change in stimulation mode.

CONCLUSION:

This study showed no differences between the two stimulation modes in the clinical behavior assessed by quality of life and functional class, and in the functional behavior, evaluated according to the ecochardiographic findings and the six-minute walk test.
Asunto(s)

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Estimulación Cardíaca Artificial / Cardiomiopatía Chagásica / Bloqueo Cardíaco Tipo de estudio: Ensayo Clínico Controlado / Estudio de etiología / Estudio observacional / Factores de riesgo Límite: Adulto / Femenino / Humanos / Masculino Idioma: Portugués Revista: Arq. bras. cardiol Asunto de la revista: Cardiología Año: 2007 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade de São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Estimulación Cardíaca Artificial / Cardiomiopatía Chagásica / Bloqueo Cardíaco Tipo de estudio: Ensayo Clínico Controlado / Estudio de etiología / Estudio observacional / Factores de riesgo Límite: Adulto / Femenino / Humanos / Masculino Idioma: Portugués Revista: Arq. bras. cardiol Asunto de la revista: Cardiología Año: 2007 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade de São Paulo/BR