Avaliação da função cardíaca por ressonância magnética com seqüências em equilíbrio estável: segmentadas × tempo real / Assessment of cardiac function by magnetic resonance imaging: segmented x real-time steady-state free precession sequences
Bezerra, Leonardo Bernardo; Marchiori, Edson; Pontes, Paulo V.
  • Bezerra, Leonardo Bernardo; Universidade Federal do Rio de Janeiro. Rio de Janeiro. BR
  • Marchiori, Edson; Universidade Federal do Rio de Janeiro. Rio de Janeiro. BR
  • Pontes, Paulo V; Universidade Federal Fluminense. Niterói. BR
Radiol. bras ; 39(5): 333-339, set.-out. 2006. ilus, graf, tab
Artículo en Portugués | LILACS | ID: lil-446725
RESUMO

OBJETIVO:

Comparar os índices de função sistólica ventricular obtidos entre as seqüências de cine-ressonância magnética em equilíbrio estável, em tempo real e acoplada ao eletrocardiograma, em pacientes com ritmo regular ou não.

MATERIAIS E MÉTODOS:

Foram comparados a fração de ejeção e os volumes diastólico e sistólico finais, em 31 pacientes, 11 com ritmo cardíaco irregular e 20 com ritmo cardíaco sinusal regular, utilizando-se seqüências segmentadas acopladas ao eletrocardiograma e em tempo real. O tratamento estatístico foi feito através da correlação de Pearson e a concordância de Bland-Altman, com p < 0,01.

RESULTADOS:

As aquisições em tempo real demonstraram borramento dos contornos endocárdicos, mas ambas as seqüências tiveram forte correlação positiva entre os valores obtidos fração de ejeção, r = 0,94; volume diastólico final, r = 0,93; volume sistólico final, r = 0,98. A análise dos 11 pacientes com ritmo irregular não demonstrou diferença estatisticamente significativa, apesar da menor relação de contraste sangue-miocárdio.

CONCLUSÃO:

Seqüências em tempo real podem ser utilizadas para a análise da função cardíaca, independente do ritmo cardíaco dos pacientes.
ABSTRACT

OBJECTIVE:

To compare ventricular systolic parameters on segmented and real-time steady-state free precession cine-MRI sequences and ECG-gated MRI in patients presenting or not with cardiac arrhythmias. MATERIALS AND

METHODS:

Ejection fraction and end-diastolic/end-systolic volumes have been compared in 31 patients, 11 presenting with cardiac arrhythmias, and 20 with regular sinus rhythm, using ECG-gated segmented and real-time sequences. The statistical analysis was performed using Pearson's correlation and Bland-Altman agreement plot, with p < 0.01.

RESULTS:

Real-time acquisitions demonstrated endocardial borders blurring effects, but both sequences presented a clear, positive correlation ejection fraction r = 0.94; end-diastolic volume r = 0.93 and end-systolic volume r = 0.98. The assessment of 11 patients with arrhythmias has not demonstrated a statistically significant difference, despite the lower blood pool-myocardial contrast ratio.

CONCLUSION:

Real-time sequences may be utilized for cardiac function assessment, regardless the patient's cardiac rhythm.
Asunto(s)
Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Volumen Sistólico / Función Ventricular / Imagen por Resonancia Cinemagnética / Electrocardiografía Tipo de estudio: Estudio diagnóstico Idioma: Portugués Revista: Radiol. bras Asunto de la revista: Diagnóstico por Imagen / Radiología Año: 2006 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade Federal Fluminense/BR / Universidade Federal do Rio de Janeiro/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Volumen Sistólico / Función Ventricular / Imagen por Resonancia Cinemagnética / Electrocardiografía Tipo de estudio: Estudio diagnóstico Idioma: Portugués Revista: Radiol. bras Asunto de la revista: Diagnóstico por Imagen / Radiología Año: 2006 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade Federal Fluminense/BR / Universidade Federal do Rio de Janeiro/BR