Your browser doesn't support javascript.
loading
Medida da distância reflexo margem por meio de processamento computadorizado de imagens em usuários de lentes de contato rígidas / Margin reflex distance measure by computerized image processing in rigid contact lens wearers
Burmann, Tiana Gabriela; Valiatti, Fabiana Borba; Correa, Zélia Maria; Bayer, Márcia; Marcon, Ítalo.
  • Burmann, Tiana Gabriela; Universidade de São Paulo. Faculdade de Medicina de Ribeirão Preto. Ribeirão Preto. BR
  • Valiatti, Fabiana Borba; ISCMPA. Porto Alegre. BR
  • Correa, Zélia Maria; ISCMPA. Setor de Retina e Tumores do Serviço de Oftalmologia. Porto Alegre. BR
  • Bayer, Márcia; ISCMPA. Porto Alegre. BR
  • Marcon, Ítalo; ISCMPA. Porto Alegre. BR
Arq. bras. oftalmol ; 71(1): 34-37, jan.-fev. 2008. ilus, tab
Artículo en Portugués | LILACS | ID: lil-480013
RESUMO
OBJETIVO: Apresentar um método novo, baseado no processamento computadorizado de imagens, para quantificar a distância reflexo margem (MRD). MÉTODOS: Selecionamos para o estudo pacientes do Setor de Lentes de Contato do Serviço de Oftalmologia da Santa Casa de Porto Alegre que foram divididos em dois grupos: o primeiro foi composto por pacientes usuários de lentes de contato rígidas (63 olhos) e o segundo por pacientes que foram encaminhados para adaptação de lentes de contato sem história prévia de uso das mesmas (30 olhos). Todos os pacientes foram fotografados com o auxílio de uma câmera fotográfica digital (Nikon Coolpix 4300). A distância reflexo margem foi medida por processamento computadorizado de imagens utilizando o programa Image J. Foram excluídos do estudo pacientes submetidos a cirurgias intra-oculares ou palpebrais, pacientes apresentando ptose congênita e pacientes que ao exame biomicroscópico apresentavam conjuntivite papilar gigante. RESULTADOS: O método utilizado para quantificar distância reflexo margem parece bastante simples e aparentemente mais sensível e específico. O valor médio da distância reflexo margem no grupo caso foi 2,46 mm e no grupo controle 2,72 mm. Dessa forma, observou-se uma tendência de diminuir a distância reflexo margem com o uso de lentes rígidas, embora esses dados não tenham sido estatisticamente significativos (p=0,22). Observa-se também que os valores de distância reflexo margem apresentam uma variabilidade muito maior no grupo caso (41,46 por cento) do que no controle (28,96 por cento), que se apresenta mais homogêneo. CONCLUSÃO: Esse estudo introduziu uma metodologia inovadora para medir a distância reflexo margem utilizando o processamento computadorizado de imagens. Esse método é acessível e pode auxiliar no acompanhamento da distância reflexo margem de pacientes usuários de lentes de contato, especialmente rígidas.
ABSTRACT
PURPOSE: To measure the MRD (margin reflex distance) in rigid contact lens wearers and controls by a new method, based on computerized image processing. METHOD: The patients were selected from the Contact Lens Sector of the Ophthalmology Service at the "Complexo Hospitalar Santa Casa de Porto Alegre", and they were divided into two groups: the first was formed of rigid contact lens wearers (63 eyes) and the second of patients without previous history of contact lens wear (30 eyes). All patients were photographed with a digital camera (Nikon Coolpix 4300). The margin reflex distance was measured by a computerized image processing using the Image J program. The study excluded patients that underwent any kind of intraocular or eyelid surgery, patients with congenital ptosis and patients with giant papillae conjunctivitis. RESULTS: The method utilized to measure margin reflex distance seems simple and more accurate. The average value of the margin reflex distance in the case group was 2.46 mm and in the control group 2.72 mm. The study shows that there is a tendency of decreasing the margin reflex distance with contact lens wear although the data were not statistically significant (p=0.22). The margin reflex distance values show a greater variability in the case group (41.46 percent) than in the control group (28.96 percent), that is more homogeneous. CONCLUSION: This study introduced a new method to measure the margin reflex distance using computerized image processing. This method is accessible and could help in follow-up of the margin reflex distance in contact lens wearers, specially those rigid.
Asunto(s)

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Blefaroptosis / Procesamiento de Imagen Asistido por Computador / Lentes de Contacto Tipo de estudio: Estudio diagnóstico / Estudio de etiología / Estudio observacional Límite: Adulto / Femenino / Humanos / Masculino Idioma: Portugués Revista: Arq. bras. oftalmol Asunto de la revista: Oftalmología Año: 2008 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: ISCMPA/BR / Universidade de São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Blefaroptosis / Procesamiento de Imagen Asistido por Computador / Lentes de Contacto Tipo de estudio: Estudio diagnóstico / Estudio de etiología / Estudio observacional Límite: Adulto / Femenino / Humanos / Masculino Idioma: Portugués Revista: Arq. bras. oftalmol Asunto de la revista: Oftalmología Año: 2008 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: ISCMPA/BR / Universidade de São Paulo/BR