Your browser doesn't support javascript.
loading
Precisão da técnica de absorciometria de raios-x de dupla energia na determinação da composição corporal em gatos / Precision of dual energy x-ray absorptiometry for body composition measurements in cats
Borges, N. C; Vasconcellos, R. S; Canola, J. C; Paula, F. J. A; Carciofi, A. C; Pereira, G. T.
  • Borges, N. C; UFG. Escola de Veterinária. Goiânia. BR
  • Vasconcellos, R. S; UNESP. Faculdade de Ciências Agrárias e Veterinárias. Jaboticabal. BR
  • Canola, J. C; UNESP. Faculdade de Ciências Agrárias e Veterinárias. Jaboticabal. BR
  • Paula, F. J. A; USP. Faculdade de Medicina. Ribeirão Preto. BR
  • Carciofi, A. C; UNESP. Faculdade de Ciências Agrárias e Veterinárias. Jaboticabal. BR
  • Pereira, G. T; UNESP. Faculdade de Ciências Agrárias e Veterinárias. Jaboticabal. BR
Arq. bras. med. vet. zootec ; 60(1): 263-266, fev. 2008. tab
Artículo en Portugués | LILACS | ID: lil-483286
ABSTRACT
A short-term precision error of the individual subject and the DEXA technique, such as the effect of the repositioning of the cat on the examination table, were established. Four neutered adult cats (BW=4342g) and three females (BW=3459g) were submitted to five repeated scans with and without repositioning between them. Precision was estimated from the mean of the five measurements and expressed by the individual coefficient of variation (CV). The precision error of the technique was estimated by the variance of scan pool (n=35) and expressed in CV for the technique (CVt). The degrees of freedom and confidence intervals were determined to avoid underestimation of precision errors. Bone mineral content (BMC), lean mass (LM), and fat mass (FM) averages were higher (P<0.05) when animals were repositioned. The CVt was significantly higher (P<0.05) for bone mineral density (BMD), LM, and FM when the animals were repositioned. For short-term precision measurements, the repositioning of the animal was important to establish the precision of the technique. The dual energy x-ray absorptiometry method provided precision for body composition measurements in adult cats.
Asunto(s)

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Rayos X / Composición Corporal / Absorciometría de Fotón / Gatos Límite: Animales Idioma: Portugués Revista: Arq. bras. med. vet. zootec Asunto de la revista: Medicina Veterinaria Año: 2008 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: UFG/BR / UNESP/BR / USP/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Rayos X / Composición Corporal / Absorciometría de Fotón / Gatos Límite: Animales Idioma: Portugués Revista: Arq. bras. med. vet. zootec Asunto de la revista: Medicina Veterinaria Año: 2008 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: UFG/BR / UNESP/BR / USP/BR