Your browser doesn't support javascript.
loading
Efeito da estimulação elétrica transcutânea em alta freqüência no músculo tríceps sural após esmagamento do nervo ciático em ratos Wistar / Effect of high frequency transcutaneous electrical stimulation on triceps sural after sciatic nerve injury in Wistar rats
Abrahão, Fabiana; Vialle, Nathália Thalita Carvalho; Farias, Thatiane Gazzoli; Marinho, Raul Oscar Feitosa; Lopes, Camila Madeira Tavares; Lima, Januário Gomes Mourão e.
  • Abrahão, Fabiana; Centro Universitário Augusto Motta. BR
  • Vialle, Nathália Thalita Carvalho; Centro Universitário Augusto Motta. BR
  • Farias, Thatiane Gazzoli; Centro Universitário Augusto Motta. BR
  • Marinho, Raul Oscar Feitosa; Centro Universitário Augusto Motta. BR
  • Lopes, Camila Madeira Tavares; Centro Universitário Augusto Motta. BR
  • Lima, Januário Gomes Mourão e; Centro Universitário Augusto Motta. BR
Fisioter. Bras ; 9(1): 29-32, jan.-fev. 2008.
Artículo en Portugués | LILACS | ID: lil-491113
RESUMO
O objetivo deste estudo foi avaliar o efeito da estimulação elétrica transcutânea de alta freqüência nas alterações morfológicas do músculo tríceps sural depois da lesão nervosa periférica do nervo ciático em ratos. Quarenta ratos foram divididos em 4 grupos controle negativo (sem lesão), controle positivo (com lesão), lesados e tratados com 4 mA e lesados e tratados com 6 mA. Entre o grupo controle positivo (5,7 ± 2,4) e controle negativo (36,3 ± 6,15) observamos uma diminuição significativa na densidade relativa de tecido muscular e conjuntivo, demonstrando a efetividade do modelo experimental. Entre os grupos tratados não houve diferença estatística, entretanto, ocorreu um aumento significativo na densidade relativa entre os grupos tratados com 4 mA (16,35 ± 0,46) e 6 mA (14,4 ± 2,63) em relação ao grupo controle positivo (5,7 ± 2,4), indicando a diminuição da proliferação de tecido conjuntivo nas amostras analisadas. Nossos resultados indicam que a estimulação elétrica transcutânea de alta freqüência, dentro desses parâmetros, foi efetiva na diminuição da proliferação de tecido conjuntivo no grupo muscular tríceps sural de ratos após lesão nervosa periférica por esmagamento do nervo ciático.
ABSTRACT
The aim of this study was to evaluate the effect of the transcutaneous electric stimulation of high frequency in the morphological alterations of the triceps surae muscle after peripheral nervous injury of the sciatic nerve in rats. Forty rats were divided into 4 groups negative control (without injury), positive control (with injury), injured and treated with 4 mA and injured and treated with 6 mA. Between the positive control group (5.7 ± 2.4) and negative control group (36.3 ± 6.15) it was observed a significant decrease in relative density of muscular tissue and conjunctive tissue, showing the effectiveness of the experimental model. We did not observe difference between the treated groups. However, a significant increase in the relative density occurred between the treated groups with 4 mA (16.35 ± 0.46) and 6 mA (14.4 ± 2.63) in relation to the positive control group (5.7 ± 2.4), indicating the reduction of the conjunctive tissue proliferation in the analyzed samples. Our results indicate that the transcutaneous electric stimulation of high frequency, within these parameters, was effective in reducing conjunctive tissue proliferation in triceps surae muscle of rats after peripheral nervous injury for crushing of the sciatic nerve.
Asunto(s)
Buscar en Google
Índice: LILACS (Américas) Asunto principal: Nervio Ciático / Estimulación Eléctrica Transcutánea del Nervio / Tejido Conectivo Tipo de estudio: Estudio de tamizaje Idioma: Portugués Revista: Fisioter. Bras Asunto de la revista: MEDICINA FISICA E REABILITACAO Año: 2008 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Centro Universitário Augusto Motta/BR

Similares

MEDLINE

...
LILACS

LIS

Buscar en Google
Índice: LILACS (Américas) Asunto principal: Nervio Ciático / Estimulación Eléctrica Transcutánea del Nervio / Tejido Conectivo Tipo de estudio: Estudio de tamizaje Idioma: Portugués Revista: Fisioter. Bras Asunto de la revista: MEDICINA FISICA E REABILITACAO Año: 2008 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Centro Universitário Augusto Motta/BR