Controle da qualidade das preparações de heparina disponíveis no Brasil: implicações na cirurgia cardiovascular / Heparin quality control in the Brazilian market: implications in the cardiovascular surgery
Melo, Eduardo I; Pereira, Mariana S; Cunha, Rodrigo S; Sá, Mauro Paes Leme de; Mourão, Paulo A. S.
  • Melo, Eduardo I; Hospital Universitário Clementino Fraga Filho. Laboratório de Tecido Conjuntivo.
  • Pereira, Mariana S; Hospital Universitário Clementino Fraga Filho. Laboratório de Tecido Conjuntivo.
  • Cunha, Rodrigo S; UFRJ. FM. Departamento de Cirurgia.
  • Sá, Mauro Paes Leme de; UFRJ. FM. Departamento de Cirurgia.
  • Mourão, Paulo A. S; Hospital Universitário Clementino Fraga Filho. Laboratório de Tecido Conjuntivo.
Rev. bras. cir. cardiovasc ; 23(2): 169-174, abr.-jun. 2008. graf, tab
Artículo en Inglés, Portugués | LILACS | ID: lil-492968
RESUMO

INTRODUÇÃO:

A mudança na marca da heparina rotineiramente utilizada nas cirurgias cardíacas no Brasil tem sido acompanhada por aumento do número de casos de discrasia sanguínea, aumento de reoperações e efeitos adversos em nossa Instituição e em outras.

MÉTODOS:

Foram avaliadas no Laboratório de Tecido Conjuntivo do HUCFF/UFRJ, quatro preparações disponíveis e comparadas à heparina retirada do mercado (Liquemine) e ao padrão de controle internacional. As preparações de heparina foram submetidas à ressonância nuclear magnética para avaliação da integridade estrutural, bem como avaliação de sua eficácia anticoagulante.

RESULTADOS:

Houve diferença significativa quanto à atividade anticoagulante entre as amostras. Também se observou a presença de contaminação com dermatam sulfato, amostras degradadas quimicamente e com significativa alteração do peso molecular.

CONCLUSÃO:

Das amostras estudadas, nenhuma atendeu aos requisitos de segurança para utilização em cirurgias cardíacas com circulação extracorpórea. Nenhuma delas apresentou a qualidade semelhante ao Liquemine, não mais disponível no mercado brasileiro.
ABSTRACT

INTRODUCTION:

The change in the heparin solution trade mark in Brazil that had been commonly used in cardiac surgery has shown increased number in the coagulopathy, re-exploration and other side effects in our Institution and others.

METHODS:

All four different heparin solutions available in the Brazilian market were studied in the Connective Tissue Lab, HUCFF, UFRJ and compared to the Liquemine (out of the market) and the international control solution. All samples were evaluated by magnetic nuclear resonance as well as their anticoagulant effectiveness.

RESULTS:

There were significant differences among them regarding the anticoagulant activity. It was also observed contamination with other dermatan sulfate, samples chemically degraded and with significant change in the molecular weight.

CONCLUSION:

Among the studied samples, none of them can offer security in cardiac surgeries on pump. None of them has demonstrated similar quality to Liquemine, which is not available in the Brazilian market.
Asunto(s)

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Procedimientos Quirúrgicos Cardiovasculares / Heparina / Industria Farmacéutica / Anticoagulantes Límite: Humanos País/Región como asunto: America del Sur / Brasil Idioma: Inglés / Portugués Revista: Rev. bras. cir. cardiovasc Asunto de la revista: Cardiología / Cirugía General Año: 2008 Tipo del documento: Artículo País de afiliación: Brasil

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Procedimientos Quirúrgicos Cardiovasculares / Heparina / Industria Farmacéutica / Anticoagulantes Límite: Humanos País/Región como asunto: America del Sur / Brasil Idioma: Inglés / Portugués Revista: Rev. bras. cir. cardiovasc Asunto de la revista: Cardiología / Cirugía General Año: 2008 Tipo del documento: Artículo País de afiliación: Brasil