Avaliação da superfície dentinária com o microscópio clínico após remoção de retentor intra-radicular utilizando o ultra-som / Evaluation of dentinal surface with clinical microscope after intra-radicularretainer removal using ultrasound
RGO (Porto Alegre)
;
56(3): 267-273, jul.-set. 2008. ilus, tab
Artículo
en Portugués
| LILACS, BBO
| ID: lil-495231
RESUMO
Objetivo:
Avaliar o tempo despendido e possíveis linhas de fissura, trincas e outros danos causados na superfície dentinária ao redor do retentor intra-radicular submetido à vibração ultra-sônica para a sua remoção, utilizando o microscópio clínico.Métodos:
Foram utilizadas 15 raízes de incisivos centrais inferiores bovinos, portadoras de retentores intra-radiculares Flexi-Post nº 3 cimentados com o cimento resinoso RelyX CRA® e incluídas em um alvéolo artificial, envoltas com uma camada de silicone. Os retentores foram submetidos à vibração ultra-sônica com o aparelho ENAC modelo EO-5 na sua potência máxima e, após a remoção, foi realizada uma avaliação a olho nu e outra com o microscópio clínico nos aumentos de 5, 8, 12,5 e 20 vezes.Resultados:
Os resultados mostraram que nenhuma superfície dentinária apresentou linhas de fissura, trincas ou outros danos, e que o tempo médio para remoção dos retentores foi de 13,25 minutos.Conclusão:
O ultra-som demonstrou ser um aparelho eficaz e seguro para a remoção de retentores intra-radiculares.ABSTRACT
Objective:
To evaluate the time spent and possible fissure lines, fractures and other damage caused on the dentinal surface around the intra-radicular retainer submitted to ultrasonic vibration to remove it, using a clinical microscope.Methods:
The roots of 15 bovine mandibular central incisors were used. These contained Flexi-Post No. 3 intra-radicular retainers cemented with RelyX CRA® resinous cement and were included in an artificial alveolus, surrounded by a layer of silicone. The retainers were submitted to ultrasonic vibration with the ENAC model EO-5 appliance at maximum power, and after removal, an evaluation was made by the naked eye, and another with a clinical microscope, at magnifications of 5, 8, 12.5 and 20 times.Results:
The results showed that no dentinal surface presented fissure lines, cracks or other damage, and that the mean time for removal of the retainers was 13.25 minutes.Conclusion:
Ultrasound was shown to be an efficient and safe appliance for intra-radicular retainer removal.
Texto completo:
Disponible
Índice:
LILACS (Américas)
Asunto principal:
Ultrasonido
/
Técnica de Perno Muñón
/
Dentina
Tipo de estudio:
Estudios de evaluación
Límite:
Animales
Idioma:
Portugués
Revista:
RGO (Porto Alegre)
Asunto de la revista:
Odontología
Año:
2008
Tipo del documento:
Artículo
País de afiliación:
Brasil
Institución/País de afiliación:
Centro de Pesquisas Odontológicas São Leopoldo Mandic/BR
Similares
MEDLINE
...
LILACS
LIS