Materiais absorvíveis na cirurgia da cranioestenose: revisão de 72 casos operados com 2 anos de acompanhamento / Resorbable internal fixation in 72 craniosynostosis surgery in a 2 year follow-up
Turrer, Clarissa Leite; Val Filho, José Aloysio da Costa; Valadares, Friederike Wollf; Tibúrcio, Jacqueline; Ferreira, Felipe Pacheco Martins.
  • Turrer, Clarissa Leite; Hospital Universitário São José. Belo Horizonte. BR
  • Val Filho, José Aloysio da Costa; Hospital Biocor. Departamento de Neurocirurgia infantil. Belo Horizonte. BR
  • Valadares, Friederike Wollf; Hospital Biocor. Belo Horizonte. BR
  • Tibúrcio, Jacqueline; Universidade Federal de Minas Gerais. Belo Horizonte. BR
  • Ferreira, Felipe Pacheco Martins; Hospital Universitário São José. Belo Horizonte. BR
Rev. Soc. Bras. Cir. Plást., (1997) ; 23(1): 31-36, jan.-mar. 2008. ilus, graf
Artículo en Portugués | LILACS | ID: lil-501677
RESUMO
A cranioestenose ou craniosinostose é o fechamentoprecoce das suturas cranianas, que pode restringir o crescimentoencefálico, levando a seqüelas como hipertensão intracraniana,distúrbios de desenvolvimento e alterações morfológicas doesqueleto craniofacial. Nos últimos dez anos, o tratamento cirúrgicoda cranioestenose evoluiu muito em decorrência da introdução denovos materiais para osteossíntese e fixação da barra supra-orbitária.

Objetivo:

Avaliar a incidência de complicações e intercorrências nosítio operatório associadas ao uso de materiais absorvíveis empacientes submetidos a tratamento cirúrgico de cranioestenoses(co-polímero polilacticoglicólico 82-18%).

Método:

Estudo retrospectivoque avaliou 72 pacientes, no período de março de 2002 adezembro de 2005, comparando dois grupos grupo controle, quenão utilizou o material; e grupo de estudo, que utilizou. As variáveis dedesfecho foram clínicas presença de deiscência de ferida operatória,seroma e reintervenção cirúrgica no sítio operatório.

Resultados:

Nãohouve diferença estatisticamente significativa na freqüência dasvariáveis estudadas à comparação dos dois grupos.

Conclusão:

Aosteossíntese com sistemas absorvíveis em cirurgia craniofacialpediátrica é segura e proporciona maior estabilidade de resultados,sem correlação com intercorrências pós-operatórias relacionadas àincidência de reações em sítio operatório.
ABSTRACT
The craniostenose or craniosynostose is the earlyclosure of cranial sutures that can limit encephalic growth withsequelas like cranial hypertension, growth disturbs andmorphologic alterations of craniofacial skeleton. In the last tenyears, the surgical treatment of the craniostenose has developeda lot due to the introduction of new materials for osteosyntheseand supraorbital fixation.

Objective:

Evaluate the incidence ofcomplications in the operative site associated with thereabsorbable materials in patients submitted to surgicaltreatment of craniosynostose (polilacticoglicolico co-polymers82-18%).

Methods:

Retrospective study that evaluated 72patients from March 2002 to December 2005 comparing 2groups – control group that didn’t use the material and groupthat used. The results were evaluated clinically presence ofdehiscence on operative wound, seroma and surgicalreintervention.

Results:

No statistic difference in the frequence ofthe 2 groups compared.

Conclusion:

The osteosynthese withreabsorbable systems used in pediatric craniofacial surgery aresafe and afford more stability of results without correlated postoperativecomplications due to local reactions.
Asunto(s)

Buscar en Google
Índice: LILACS (Américas) Asunto principal: Materiales Biocompatibles / Anomalías Craneofaciales / Suturas Craneales / Craneosinostosis Tipo de estudio: Estudio diagnóstico / Estudios de evaluación / Estudio observacional / Factores de riesgo Límite: Niño / Femenino / Humanos / Masculino Idioma: Portugués Revista: Rev. Soc. Bras. Cir. Plást., (1997) Asunto de la revista: Cirugía General Año: 2008 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Hospital Biocor/BR / Hospital Universitário São José/BR / Universidade Federal de Minas Gerais/BR

Similares

MEDLINE

...
LILACS

LIS

Buscar en Google
Índice: LILACS (Américas) Asunto principal: Materiales Biocompatibles / Anomalías Craneofaciales / Suturas Craneales / Craneosinostosis Tipo de estudio: Estudio diagnóstico / Estudios de evaluación / Estudio observacional / Factores de riesgo Límite: Niño / Femenino / Humanos / Masculino Idioma: Portugués Revista: Rev. Soc. Bras. Cir. Plást., (1997) Asunto de la revista: Cirugía General Año: 2008 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Hospital Biocor/BR / Hospital Universitário São José/BR / Universidade Federal de Minas Gerais/BR