Your browser doesn't support javascript.
loading
Análise fotoelástica da distribuição de tensões induzidas por infra-estruturas implanto-suportadas após soldagem a laser ou retificação de cilindros / Photoelastic analysis of stress distribution induced by implant supported frameworks after laser welding or refinement of cylinders
Damaceno, Alessandra Regina Derogis; Nobilo, Mauro Antonio de Arruda; Henriques, Guilherme Elias Pessanha; Mesquita, Marcelo Ferraz.
  • Damaceno, Alessandra Regina Derogis; Unicamp. Faculdade de Odontologia de Piracicaba. Programa de Pós-Graduação em Clínica Odontológica. Piracicaba. BR
  • Nobilo, Mauro Antonio de Arruda; Unicamp. Faculdade de Odontologia de Piracicaba. Departamento de Prótese e Periodontia. Piracicaba. BR
  • Henriques, Guilherme Elias Pessanha; Unicamp. Faculdade de Odontologia de Piracicaba. Departamento de Prótese e Periodontia. Piracicaba. BR
  • Mesquita, Marcelo Ferraz; Unicamp. Faculdade de Odontologia de Piracicaba. Departamento de Prótese e Periodontia. Piracicaba. BR
Ciênc. odontol. bras ; 11(01): 27-34, jan.-mar. 2008. ilus
Artículo en Portugués | LILACS, BBO | ID: lil-502327
RESUMO
O assentamento passivo de próteses fixas implanto-suportadas pode ser obtido por procedimentos laboratoriais. O objetivo deste estudo foi avaliar comparativamente a formação de tensões induzidas por infra-estruturas implanto-suportadas obtidaspor duas técnicas através da análise fotoelástica. Dois grupos de infra-estrututas em titânio comercialmente puro foram obtidos sobre uma matriz metálica I) três infra-estruturas confeccionadas pela técnica da soldagem de borda de cilindrose II) três infra-estruturas fundidas em monobloco e submetidas ao sistema de retificação de cilindros. Após análise emmicroscopia óptica, apenas a estrutura mais bem adaptada de cada grupo foi submetida à análise de tensões, em três seqüências de aperto dos parafusos protéticos. Após, a estrutura do grupo II sofreu secção e soldagem e foi novamente submetida à análise fotoelástica. Os resultados mostraram maior magnitude de tensões com a seqüência de aperto de parafusos daesquerda para direita e vice-versa, para ambos os grupos. A estrutura do grupo I induziu menor concentração de tensões,mesmo tendo apresentado maiores valores de desadaptação (165μm) comparada ao grupo II antes (54μm) e após secção e soldagem a laser (117μm). A técnica da soldagem de borda a laser, associada à seqüência de aperto do parafuso protéticodo centro para as extremidades, obteve melhores resultados formação de tensões para este tipo de reabilitação.
ABSTRACT
The passive fit of implanted-supported fixed rehabilitation may be achieved with laboratorial procedures. The aim of this study was evaluate the stress formation induced by two techniques indicated to obtain implant-supported fixed prostheses with satisfactory passive fit by means of photoelastic analysis. Two titanium casts groups were fabricated in a metallic master cast Group I- three frameworks fabricated by laser welded cylinder technique and Group II- three frameworks cast in one-piece and submitted to cylinder refinement system. After optical microscopy valuation, only the better-fit frameworkof both groups was submitted to the photoelastic analysis, testing three screw tightening sequences. Subsequent to the first analysis the selective framework of Group II was sectioned and laser welded to be submitted to a new evaluation. Results showed superior stress magnitude formation in screw tightening sequences from left to right and vice-versa of both groups,while medial to distal screw tightening sequence presented better results to Branemark protocolo rehabilitation. The group I framework illustrated better results, even though had showed superior values of misfit (165μm) compared to group II before (54μm) and after section and laser welded (117μm). Laser welded cylinder technique achieved better results to thistype of rehabilitation mainly allied to the medial to distal prosthetic screw tightening sequence.
Asunto(s)
Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Soldadura Dental / Prótesis Dental de Soporte Implantado Tipo de estudio: Guía de Práctica Clínica Idioma: Portugués Revista: Ciênc. odontol. bras Asunto de la revista: Odontología Año: 2008 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Unicamp/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Soldadura Dental / Prótesis Dental de Soporte Implantado Tipo de estudio: Guía de Práctica Clínica Idioma: Portugués Revista: Ciênc. odontol. bras Asunto de la revista: Odontología Año: 2008 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Unicamp/BR