Trauma abdominal penetrante consecutivo à corrente elétrica industrial / Penetrating abdominal trauma following industrial eletric current
Rev. Col. Bras. Cir
;
27(4): 287-289, jul.-ago. 2000. ilus
Artículo
en Portugués
| LILACS
| ID: lil-508290
ABSTRACT
The authors present a case report of a victim of high power electric shock. The main electric lesion was a penetrating abdominal wound with loss of substance of the abdominal wall and an electric lesion of the hepatic segment and of the gallbladder. The surgical treatment included hepatic segmentectomy, cholecystectomy, repair of the abdominal wall with Marlex prosthesis and skin graft, besides the debridment of the lesions of extremities. The postoperative evolution was satisfactory and the follow-up for 6 months didn't show any sequelae.