Your browser doesn't support javascript.
loading
Utilização da relação potência-tempo até exaustão em testes de caminhada para avaliação da aptidão aeróbia / Use of the power-time until exhaustion relantionship in walk tests to evaluate aerobic fitness
Puga, Guilherme Morais; Nakamura, Fábio Yuzo; Simões, Herbert Gustavo; Kokubun, Eduardo; Campbell, Carmen Silvia Grubert.
  • Puga, Guilherme Morais; Universidade Católica de Brasília. BR
  • Nakamura, Fábio Yuzo; Universidade Estadual de Londrina. BR
  • Simões, Herbert Gustavo; Universidade Católica de Brasília. BR
  • Kokubun, Eduardo; Universidade Estadual Paulista. Rio Claro. BR
  • Campbell, Carmen Silvia Grubert; Universidade Católica de Brasília. BR
Rev. bras. med. esporte ; 15(3): 209-213, maio-jun. 2009. graf, tab
Artículo en Portugués | LILACS | ID: lil-517538
RESUMO
O objetivo do presente estudo foi avaliar a aptidão aeróbia em testes de caminhada com carga externa aplicada por meio da inclinação da esteira, a partir da relação não linear entre inclinação da esteira e tempo até a exaustão em velocidade fixa. Doze indivíduos do gênero masculino com 23,2 ± 2,7 anos de idade, 74,0 ± 7,9kg de massa corporal e 23,7 ± 2,5kg·(m²)-1 de IMC, realizaram duas etapas de testes de caminhada em esteira ergométrica com velocidade fixa de 5,5km·h-1 em todos os testes e sobrecarga de intensidade aplicada por meio de inclinação da esteira ( por cento). A etapa 1 consistiu de três testes retangulares até a exaustão voluntária, nas intensidades de 18 por cento, 20 por cento e 22 por cento de inclinação, para determinação dos parâmetros do modelo de potência crítica por dois modelos lineares e um hiperbólico. A etapa 2 consistiu na determinação da intensidade correspondente ao máximo estado estável de lactato sanguíneo (MEEL). ANOVA demonstrou que o modelo hiperbólico (15,4 ± 1,1 por cento) resultou em estimativa significativamente menor que os outros dois modelos lineares inclinação-tempo-1 (16,0 ± 1,0 por cento) e hiperbólico linearizado tempo-1-inclinação (15,9 ± 1,0 por cento), porém, houve alta correlação entre os modelos. Os dois modelos lineares superestimaram a intensidade do MEEL (14,1 ± 1,4 por cento), e o modelo hiperbólico, mesmo sem diferença estatística, apresentou fraca correlação, com baixa concordância em relação ao MEEL. Conclui-se que a relação inclinação-tempo até a exaustão, em testes de caminhada, não permitem a estimativa de intensidade de exercício suportável por longo período de tempo.
ABSTRACT
The aim of the present study was to evaluate aerobic fitness during walk tests with workload increased by treadmill inclination, based on non-linear relationship between treadmill inclination and time until exhaustion in steady velocity. Twelve male subjects, 23.2 ± 2.7 years old, 74.0 ± 7.9 kg of body mass and 23.7 ± 2.5 kg·(m²)-1 of BMI, performed two phases of treadmill walk tests with steady velocity during all tests of 5.5 km·h-1 and intensity workload applied on the treadmill inclination ( percent). Phase 1 consisted of tree workout tests until voluntary exhaustion at 18 percent, 20 percent and 22 percent of inclination intensity, for critical power parameters determination, by using two linear models and a hyperbolic model. Phase 2 consisted of determination of the maximal blood lactate steady state (MLSS) intensity. ANOVA showed that the hyperbolic model (15.4 ± 1.1 percent) underestimated both linear models linear inclination-time-1 (16.0 ± 1.0 percent) and hyperbolic linear time-1-inclination (15.9 ± 1.0 percent); however, there was high correlation. Both linear models overestimated the MLSS intensity (14.1 ± 1.4 percent), and although there was no difference between the MLSS and the hyperbolic model, they had low correlation and there was a lower agreement. In conclusion, the inclination-time to exhaustion ratio in walk tests does not show an exercise intensity that can be bearable for a long period of time.
Asunto(s)

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Umbral Anaerobio / Aptitud Física / Caminata / Prueba de Esfuerzo / Lactatos Límite: Humanos / Masculino Idioma: Portugués Revista: Rev. bras. med. esporte Asunto de la revista: Medicina Deportiva Año: 2009 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade Católica de Brasília/BR / Universidade Estadual Paulista/BR / Universidade Estadual de Londrina/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Umbral Anaerobio / Aptitud Física / Caminata / Prueba de Esfuerzo / Lactatos Límite: Humanos / Masculino Idioma: Portugués Revista: Rev. bras. med. esporte Asunto de la revista: Medicina Deportiva Año: 2009 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade Católica de Brasília/BR / Universidade Estadual Paulista/BR / Universidade Estadual de Londrina/BR