In this work the variation in the toluene elimination capacity of an airlift bioreactor as a function of the toluene inlet load, using compost as the support material for the microorganisms was studied. In order to evaluate the flexibility of the reactor under changing toluene load, the toluene biodegradation was measured for flows from 2.4 x 10-2 to 0.132 m³ h-1, and a concentration range from 1.4 to 0.8 g m-3. Results show a 100 percent removal efficiency (RE) for minor flows, however, for a flow increase of 450 percent the RE decreased 40 percent, reflecting the equipments weak flexibility in varying flows. Meanwhile the maximum elimination capacity obtained was 230 g m-3 h-1, for toluene loads of 550 g m-3 h-1, corresponding to a flow of 0.132 m³ h-1. It was found that a average biomass concentration in suspension of 3700 g m-3, reflected EC's of 203 g m-3 h-1.