Avaliação da reprodutibilidade ultrassonográfica como método para medida da gordura abdominal e visceral / Reproducibility of ultrasonography as a method to measure abdominal and visceral fat
Diniz, Angélica Lemos Debs; Tomé, Raphael Alves Ferreira; Debs, Cecília Lemos; Carraro, Renata; Borges Roever, Leonardo; Pinto, Rogério de Melo Costa.
  • Diniz, Angélica Lemos Debs; Universidade Federal de Uberlândia. Uberlândia. BR
  • Tomé, Raphael Alves Ferreira; Universidade Federal de Uberlândia. Departamento de Radiologia e Diagnóstico por Imagem. Uberlândia. BR
  • Debs, Cecília Lemos; Universidade Federal de Uberlândia. Uberlândia. BR
  • Carraro, Renata; Universidade Federal de Uberlândia. Uberlândia. BR
  • Borges Roever, Leonardo; s.af
  • Pinto, Rogério de Melo Costa; Universidade Federal de Uberlândia. Uberlândia. BR
Radiol. bras ; 42(6): 353-357, nov.-dez. 2009. ilus, graf
Artículo en Inglés, Portugués | LILACS | ID: lil-536415
RESUMO
OBJETIVO: O objetivo deste estudo é avaliar a variabilidade interobservador do método ultrassonográfico para medida da gordura subcutânea, visceral e perirrenal por meio de técnica padronizada. MATERIAIS E MÉTODOS: Foram avaliados 50 pacientes entre novembro de 2006 e janeiro de 2007. A medida da espessura subcutânea foi realizada com transdutor linear de 7,5 MHz posicionado transversalmente a 1 cm acima da cicatriz umbilical. Para a gordura visceral foi utilizado transdutor de 3,5 MHz posicionado 1 cm acima da cicatriz umbilical, considerando-se a medida entre a face interna do músculo reto abdominal e a parede posterior da aorta na linha média do abdome. A gordura perirrenal foi medida no terço médio do rim direito, com transdutor posicionado na linha axilar média. RESULTADOS: A reprodutibilidade interobservador foi analisada por meio do teste t de Student, com significância de 95 por cento. Não houve diferença significativa entre as médias das medidas das gorduras subcutânea, visceral e perirrenal, com p = 0,7141, 0,7286 e 0,6368, respectivamente. As médias encontradas, com seus respectivos desvios-padrão, foram: 2,64 ± 1,37 para a espessura subcutânea, 6,84 ± 2,38 para a espessura visceral e 4,89 ± 2,6 para a espessura perirrenal. CONCLUSÃO: A ultrassonografia apresentou boa reprodutibilidade interobservador para avaliação da gordura abdominal por meio das medidas das espessuras subcutânea, visceral e perirrenal.
ABSTRACT
OBJECTIVE: The purpose of this study was to evaluate the interobserver variability of ultrasound in the measurement of subcutaneous, visceral and perirenal fat through standard technique. MATERIALS AND METHODS: From November 2006 to January 2007, 50 patients were evaluated. The subcutaneous fat thickness was measured with a 7.5 MHz linear transducer transversely positioned 1 cm above the umbilical scar. For the visceral fat, a 3.5 MHz transducer was also positioned 1 cm above the umbilical scar, considering the distance between the internal surface of the abdominal rectus muscle and the posterior aortic wall in the abdominal midline. The perirenal fat was measured in the middle third of the right kidney, with the transducer positioned at the axillary midline. RESULTS: The t-Student test was utilized to analyze the interobserver reproducibility with significance level of 95 percent. No statistically significant difference was observed among mean values for subcutaneous, visceral and perirenal fat (p = 0.7141, 0.7286 and 0.6368, respectively). Mean and standard deviation corresponded to 2.64 ± 1.37 for subcutaneous thickness, 6.84 ± 2.38 for visceral fat, and 4.89 ± 2.6 for perirenal fat. CONCLUSION: Ultrasound presented a good interobserver reproducibility in the evaluation of abdominal fat based on measurement of subcutaneous, visceral and perirenal fat as parameters.
Asunto(s)

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Síndrome Metabólico / Grasa Abdominal / Grasa Subcutánea Abdominal / Grasa Subcutánea Límite: Adolescente / Niño / Femenino / Humanos / Masculino Idioma: Inglés / Portugués Revista: Radiol. bras Asunto de la revista: Diagnóstico por Imagen / Radiología Año: 2009 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade Federal de Uberlândia/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Síndrome Metabólico / Grasa Abdominal / Grasa Subcutánea Abdominal / Grasa Subcutánea Límite: Adolescente / Niño / Femenino / Humanos / Masculino Idioma: Inglés / Portugués Revista: Radiol. bras Asunto de la revista: Diagnóstico por Imagen / Radiología Año: 2009 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade Federal de Uberlândia/BR