Estudo da validade e confiabilidade intra e interobservador da versão modificada do teste de Schõber modificado em indivíduos com lombalgia / Study of validity and intra and inter-observer reliability of modified-modified Schrõber test in subjects with low-back pain
Fisioter. pesqui
; 16(3): 233-238, jul.-set. 2009. ilus, tab
Article
en Pt
| LILACS
| ID: lil-539083
Biblioteca responsable:
BR66.1
RESUMO
Em pacientes com lombalgia, mensura-se a amplitude de movimento (ADM) da coluna lombar por meio da versão modificada do teste de Schõber modificado (MTSM), mas suas propriedades psicométricas não são comprovadas para uso clínico. Este estudo verificou a validade e confiabilidade intra e interobservador do MTSM em indivíduos com lombalgia, comparando as medidas da ADM com as obtidas por meio de radiografia, método considerado padrão-ouro. Participaram 20 voluntários com lombalgia, de ambos os sexos, funcionários de um Hospital Universitário. O MTSM foi aplicado duas vezes por dois avaliadores. As medidas obtidas pelo teste e por radiografia foram comparadas usando o coeficiente de correlação de Pearson, obtendo-se r=0,14, ou seja, correlação fraca. O coeficiente de correlação intraclasse (CCI) dos MTSM intra-observador foi 0,96 (IC 95% 0,91;0,98) e interobservador 0,93 (IC 95% 0,84;0,97), indicando alta confiabilidade; o teste de Bland & Altman mostrou alta concordância intra e interobservador, com valores de -0,21 e -0,28, respectivamente. Embora tenha sido encontrada alta confiabilidade intra e interobservador na aplicação da versão modificada do teste de Schõber modificado, este apresentou baixa validade para medir a ADM da coluna lombar, quando comparado ao padrão-ouro...
ABSTRACT
In patients with low-back pain the lumbar spine range of motion (ROM) is often measured by the modified version of the modified Schõber test (MMST), but its psychometric properties have not been ascertained for clinical use. The purpose here was to verify intra and inter-observer validity and reliability of the MMST in subjects with low-back pain, and to compare obtained ROM measures to those obtained by radiography, taken as gold standard. The study involved 20 subjects with chronic low-back pain, of both sexes, employees at a university hospital. The MMST was applied twice by two examiners each. The Pearson correlation coefficient found when comparing measures obtained via MMST and radiography was r=0.14, showing a poor correlation between the tests. The intra-observer intraclass correlation coefficient (ICC) found was 0.96 (CI 95% 0.91;0.98), and the inter-observer ICC was 0.93 (IC 95% 0.84;0.97), showing high reliability; the Bland & Altman agreement test showed high agreement intra (-0.21) and inter-observer (-0.21). Although a high reliability both intra and inter-observer was found for the modified-modified Schõber test, the latter showed low validity in assessing lumbar spine range of motion, when compared to the gold standard...
Texto completo:
1
Índice:
LILACS
Asunto principal:
Reproducibilidad de los Resultados
/
Rango del Movimiento Articular
/
Dolor de la Región Lumbar
Límite:
Adult
/
Female
/
Humans
/
Male
Idioma:
Pt
Revista:
Fisioter. pesqui
Asunto de la revista:
MEDICINA FISICA E REABILITACAO
Año:
2009
Tipo del documento:
Article