Your browser doesn't support javascript.
loading
Valores da pressão arterial em cães pelos métodos oscilométrico e Doppler vascular / Arterial blood pressure in dogs by the oscilometric method and the Doppler ultrasonic
Cabral, R. R; Ciasca, B. D; Oliveira, V. M. C; Vaz-Curado, A. P; Larsson, M. H. M. A.
  • Cabral, R. R; Universidade de São Paulo. Faculdade de Medicina Veterinária e Zootecnia. São Paulo. BR
  • Ciasca, B. D; Universidade de São Paulo. Faculdade de Medicina Veterinária e Zootecnia. São Paulo. BR
  • Oliveira, V. M. C; Universidade de São Paulo. Faculdade de Medicina Veterinária e Zootecnia. São Paulo. BR
  • Vaz-Curado, A. P; Universidade de São Paulo. Faculdade de Medicina Veterinária e Zootecnia. São Paulo. BR
  • Larsson, M. H. M. A; Universidade de São Paulo. Faculdade de Medicina Veterinária e Zootecnia. São Paulo. BR
Arq. bras. med. vet. zootec ; 62(1): 64-71, Feb. 2010. graf, tab
Artículo en Portugués | LILACS | ID: lil-543070
RESUMO
Foram comparados dois métodos não-invasivos de medida da pressão arterial, o Doppler vascular e o oscilométrico, com o objetivo de estabelecer parâmetros que possam auxiliar no diagnóstico seguro da hipertensão arterial. Para tal, foram utilizados 45 cães, machos e fêmeas, distribuídos em três grupos de acordo com o peso, pequeno, médio e grande porte. Em cada animal, procedeu-se a mensuração por meio do Doppler vascular e, em seguida, do oscilométrico. Na obtenção da pressão arterial sistólica, não houve diferença entre os métodos nos três grupos de animais, porém, na obtenção da pressão arterial diastólica, houve diferença estatística entre o Doppler vascular e o oscilométrico nos grupos de animais de pequeno e médio porte. Pôde-se concluir que valores confiáveis de pressão sistólica podem ser obtidos tanto por meio do Doppler vascular quanto do oscilométrico. Os valores da pressão arterial diastólica obtidos pelos dois métodos não se correlacionam, principalmente nos animais de pequeno e médio porte.
ABSTRACT
Two noninvasive methods for blood pressure measurement, the oscilometric and the Doppler ultrasonic, were compaired aiming the establishment of parameters that can be helpful for the hypertension diagnosis. Forty-five dogs, males and females, were distributed in three groups, according to body weight small, medium, and large sizes. In each animal, measurement of the blood pressure was performed, first by the Doppler ultrasonic, followed by the oscilometric method. No differences were observed in sistolic arterial pressure values obtained by both methods in none of the three animal groups. However, there was an important difference in diastolic arterial pressure values obtained by these methods, especially in small and medium size dogs. It was concluded that reliable results of sistolic blood pressure can be obtained both by the Doppler ultrasonic and the oscilometric method. Diastolic blood pressure results, however, showed no correlation between these two methods, mainly in small and medium size dogs.
Asunto(s)

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Determinación de la Presión Sanguínea / Presión Arterial Tipo de estudio: Estudio diagnóstico Límite: Animales Idioma: Portugués Revista: Arq. bras. med. vet. zootec Asunto de la revista: Medicina Veterinaria Año: 2010 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade de São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Determinación de la Presión Sanguínea / Presión Arterial Tipo de estudio: Estudio diagnóstico Límite: Animales Idioma: Portugués Revista: Arq. bras. med. vet. zootec Asunto de la revista: Medicina Veterinaria Año: 2010 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade de São Paulo/BR