Fraturas da extremidade distal da tíbia tratadas pela haste intramedular e placa em ponte: comparação do tempo de exposição à radiação nos dois métodos / Fractures of distal third extremity of the tibia treated with intramedullary nail and bridge plate: comparison of radiation exposure time in the two methods
Rev. bras. ortop
;
45(2): 132-135, 2010. tab
Artículo
en Portugués
| LILACS
| ID: lil-547909
RESUMO
OBJETIVO:
Comparar o tempo de exposição à radiação nos pacientes com fratura do terço distal da tíbia tratados com haste intramedular e placa em ponte.MÉTODOS:
Em 33 fraturas foram utilizadas hastes intramedulares e em 41, placas em ponte. No grupo haste, segundo a classificação AO, 14 pacientes apresentavam fraturas do tipo A, 15 do tipo B e quatro, do tipo C. Doze pacientes sofreram fraturas fechadas e 21, expostas. No grupo placa, 10 pacientes apresentavam fraturas do tipo A, 22 do tipo B e nove do tipo C. Vinte e sete pacientes sofreram fraturas fechadas e 14 expostas.RESULTADOS:
Observou-se que existe diferença significativa no tempo de exposição à radiação entre pacientes tratados com haste e placa (p = 0,0001). O grupo tratado com haste apresentou tempo de exposição à radiação significativamente maior que o grupo com placa. Quando comparado o tipo de fratura (A, B e C), observou-se que não existe diferença significativa no tempo de exposição à radiação quando utilizada a técnica de haste (p = 0,19) e placa (p = 0,80).CONCLUSÃO:
Fraturas do terço distal da tíbia tratadas com haste intramedular apresentam um tempo de exposição à radiação significativamente maior do que as fraturas tratadas com placa em ponte, independente do tipo de fratura.ABSTRACT
OBJECTIVE:
To compare the exposure time to radiation in patients with distal third fractures of the tibia treated with intramedullary nail and bridge plate.METHODS:
In 33 fractures intramedullary nails were used, and in 41 fractures plates were used. In the intramedullary nail group, according to the AO classification, 14 patients had type A fractures, 15 patients had type B fractures and four had type C fractures. Twelve patients had closed fractures and 21 had open fractures. In the plate group, 10 patients had type A fractures, 22 patients had type B fractures and nine had type C fractures. 27 patients had closed fractures and 14 had open fractures.RESULTS:
A significant difference was observed in exposure time to radiation between the patients treated with the intramedullary nail and the plate (p = 0.0001). The group treated with the intramedullary nail had a significantly higher exposure time to the radiation than the group treated with the plate. Comparing the type of fracture (A, B and C), it was observed that there is no considerable difference in exposure time to radiation between the intramedullary nail technique (p = 0.19) and the plate technique (p = 0.80).CONCLUSION:
Fractures of distal third of the tibia treated with intramedullary nail show considerably higher exposure time to radiation than fractures treated with the bridge plate, independent of fracture type.
Texto completo:
Disponible
Índice:
LILACS (Américas)
Asunto principal:
Fracturas de la Tibia
/
Estudios de Casos y Controles
/
Fijación Intramedular de Fracturas
Tipo de estudio:
Estudio observacional
Límite:
Adolescente
/
Adulto
/
Femenino
/
Humanos
/
Masculino
Idioma:
Portugués
Revista:
Rev. bras. ortop
Asunto de la revista:
Ortopedia
Año:
2010
Tipo del documento:
Artículo
País de afiliación:
Brasil
Institución/País de afiliación:
Hospital Santa Teresa/BR
/
Hospital de Ipanema/BR
/
Universidade Federal do Rio de Janeiro/BR
Similares
MEDLINE
...
LILACS
LIS