RESUMO

OBJETIVO:

Demonstrar a sensibilidade e especificidade do teste do gelo no diagnóstico diferencial de ptose palpebral por miastenia gravis.

MÉTODOS:

Estudo prospectivo tipo ensaio clínico com grupo controle. Foi realizado o teste do gelo em pacientes portadores de ptose palpebral. Os pacientes foram divididos em 2 grupos, sendo o grupo I constituído por pacientes com miastenia gravis e o grupo II (controle) formado por pacientes portadores de ptose congênita, miogênica não-miastênica ou aponeurótica.

RESULTADOS:

Todos os pacientes do grupo I tiveram aumento da fenda palpebral de, no mínimo, 3 mm após a aplicação do gelo. Nenhum paciente do grupo II apresentou incremento da fenda palpebral após o teste.

CONCLUSÃO:

O teste do gelo mostrou-se específico para detecção de ptose palpebral de causa miastênica.
ABSTRACT

PURPOSE:

To demonstrate the sensitivity and the specificity of the ice test in the differential diagnosis of ptosis in myasthenia gravis.

METHODS:

Prospective trial with a control group. The patients were instructed to hold a frozen ice pack on the closed ptotic eyelid. They were divided into 2 groups, with group I consisting of patients with myasthenia gravis and group II (control) consisting of patients with congenital, non-myasthenic myogenic or aponeurotic ptosis.

RESULTS:

All patients in group I had increased palpebral fissure for at least 3 mm after the application of ice pack. No patient in group II showed increased palpebral fissure after the ice test.

CONCLUSION:

Ice test proved to be specific for the detection of myasthenic ptosis.
Asunto(s)

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Blefaroptosis / Frío / Hielo / Miastenia Gravis Tipo de estudio: Ensayo Clínico Controlado / Estudio diagnóstico / Estudio observacional / Factores de riesgo Límite: Adolescente / Adulto / Anciano / Femenino / Humanos / Masculino Idioma: Portugués Revista: Arq. bras. oftalmol Asunto de la revista: Oftalmología Año: 2010 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: FMABC/BR / Faculdade de Medicina do ABC/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Blefaroptosis / Frío / Hielo / Miastenia Gravis Tipo de estudio: Ensayo Clínico Controlado / Estudio diagnóstico / Estudio observacional / Factores de riesgo Límite: Adolescente / Adulto / Anciano / Femenino / Humanos / Masculino Idioma: Portugués Revista: Arq. bras. oftalmol Asunto de la revista: Oftalmología Año: 2010 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: FMABC/BR / Faculdade de Medicina do ABC/BR