Your browser doesn't support javascript.
loading
Sensibilidade e especificidade da técnica de oscilações forçadas no diagnóstico precoce da DPOC / Sensibility and specificity of the forced oscillation technique in earlier detection of COPD
Costa, Alessandra Alves da; Faria, Álvaro Camila Dias; Lopes, Agnaldo José; Jansen, José Manoel; Melo, Pedro Lopes de.
  • Costa, Alessandra Alves da; Universidade do Estado do Rio de Janeiro. Faculdade de Ciências Médicas. Disciplina de Pmeumologia. Rio de Janeiro. BR
  • Faria, Álvaro Camila Dias; Universidade do Estado do Rio de Janeiro. Faculdade de Engenharia. Instituto de Biologia. Rio de Janeiro. BR
  • Lopes, Agnaldo José; Universidade do Estado do Rio de Janeiro. Faculdade de Ciências Médicas. Disciplina de Pneumologia. Rio de Janeiro. BR
  • Jansen, José Manoel; Universidade do Estado do Rio de Janeiro. Faculdade de Ciências Médicas. Disciplina de Pneumologia. Rio de Janeiro. BR
  • Melo, Pedro Lopes de; Universidade do Estado do Rio de Janeiro. Faculdade de Engenharia. Instituto de Biologia. Rio de Janeiro. BR
Pulmäo RJ ; 17(2/4): 70-75, 2008.
Artículo en Portugués | LILACS | ID: lil-548965
RESUMO

Introdução:

O objetivo deste estudo foi avaliar a sensibilidade e a especificidade da técnica de oscilações forçadas (TOF) na detecção precoce dos estágios iniciais da doença pulmonar obstrutiva crônica (DPOC).

Metodologia:

O estudo foi realizado num grupo controle composto por 30 indivíduos saudáveis, e em 98 fumantes, que foram classificados pela espirometria emnormal (n=59) e com distúrbio ventilatório obstrutivo leve (n=39). Os parâmetros resistivos da impedância estudados foram a média da resistência respiratória total extrapolada em 0 Hz (R0), a resistência respiratória média (Rm) e a inclinação do componente resistivo da impedância (S). A reatância foi interpretada usando a média dos valores (Xm) na faixa de freqüênciaentre 4-32 Hz da complacência dinâmica (Crs,dyn) e do valor de freqüência de ressonância (Fr).

Resultados:

As resistências aumentaram significativamente com o grau de obstrução (R0, p<0,0001; Rm, p<0,0001). Foram também observadas modificações significativas nas propriedades reativas (Crs,dyn, p<0,0001; Xm, p<0,03). Os parâmetros R0, Rm e Crs,dyn apresentaramacuidade diagnóstica suficiente para identificar modificações de mecânica respiratória em pacientes sem alterações aos exames espirométricos.

Conclusão:

A TOF pode contribuir para a detecção precoce dos efeitos do tabagismo, sendo que os parâmetros mais adequados para estas análises são R0, Rm e Crs,dyn.
ABSTRACT

Introduction:

The aim of this study was to test the ability of forced oscillation technique (FOT) to describe the changes in respiratory mechanics in earlier stages of COPD.

Methodology:

The study was performed in a control group formed by 30 healthy subjects,and 98 smokers, which were classified by spirometry in normal (59 smokers) and mild airway obstruction (39 smokers). Resistive impedance data were submitted to linear regression analysis over the 4-16 Hz frequency range, which yielded the total respiratory system resistance extrapolated at 0 Hz (R0), the mean respiratory resistance (Rm), and the resistance/ frequency slope(S). Reactance data were interpreted using the mean values (Xm) over the 4-32 Hz frequency range, the dynamic compliance (Crs,dyn), and theresonant frequency (Fr) data.

Results:

The resistances increased significantly in agreement with the degree of obstruction (R0, p<0.0001; Rm, p<0.0001). Were also observed significantly modifications in reactive proprieties (Crs,dyn, p<0.0001; Xm, p<0.03). The parameters R0, Rm and Crs,dyn presented sufficient sensibility to identify respiratory mechanics modifications in patients withoutspirometric alterations.

Conclusion:

FOT can contribute to early detection of tobacco smoke effects, and the more adequate parameters to these analysis are R0, Rm e Crs,dy.
Asunto(s)
Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Oscilometría / Espirometría / Estudios de Casos y Controles / Mecánica Respiratoria / Enfermedad Pulmonar Obstructiva Crónica Tipo de estudio: Estudio diagnóstico / Estudio observacional / Estudio de tamizaje Límite: Adulto / Humanos Idioma: Portugués Revista: Pulmäo RJ Asunto de la revista: Neumología Año: 2008 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade do Estado do Rio de Janeiro/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Oscilometría / Espirometría / Estudios de Casos y Controles / Mecánica Respiratoria / Enfermedad Pulmonar Obstructiva Crónica Tipo de estudio: Estudio diagnóstico / Estudio observacional / Estudio de tamizaje Límite: Adulto / Humanos Idioma: Portugués Revista: Pulmäo RJ Asunto de la revista: Neumología Año: 2008 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade do Estado do Rio de Janeiro/BR