Your browser doesn't support javascript.
loading
Assimetria na relação escavação/disco óptico em adolescentes / Cup-to-disc ratio asymmetry in adolescents
Campos, Maria Elizabete Jimenes de; Garcia, Denny Marcos; Rodrigues, Maria de Lourdes Veronese.
  • Campos, Maria Elizabete Jimenes de; Universidade de São Paulo. Faculdade de Medicina de Ribeirão Preto. Programa de Pós-Graduação em Oftalmologia, Otorrinolaringologia e Cirurgia de Cabeça e Pescoço. Ribeirão Preto. BR
  • Garcia, Denny Marcos; Universidade de São Paulo. Faculdade de Medicina de Ribeirão Preto. Programa de Pós-Graduação em Oftalmologia, Otorrinolaringologia e Cirurgia de Cabeça e Pescoço. Ribeirão Preto. BR
  • Rodrigues, Maria de Lourdes Veronese; Universidade de São Paulo. Faculdade de Medicina de Ribeirão Preto. Departamento de Oftalmologia, Otorrinolaringologia e Cirurgia de Cabeça e Pescoço. Ribeirão Preto. BR
Arq. bras. oftalmol ; 73(3): 231-234, jun. 2010. ilus, graf
Artículo en Portugués | LILACS | ID: lil-555062
RESUMO

Objetivo:

Verificar a frequência de assimetrias superiores a 0,2 na razão escavação/disco em uma população de adolescentes.

Métodos:

Retinografias de ambos os olhos de 123 jovens foram digitalizadas na resolução de 300 pixels por polegada (300 dpi), 8 bits, padrão de cor RGB. Para a realização das medidas foi utilizado o software Image J, versão 1.42, desenvolvido pelo National Institute of Health (NIH), plataforma Java versão 1.6.

Resultados:

Os valores das diferenças, entre os dois olhos do mesmo indivíduo, na razão das medidas do diâmetro vertical da escavação/diâmetro vertical do disco óptico variaram de 0 a 0,30. A média das diferenças foi 0,07, a mediana 0,06 e o desvio padrão 0,05. Assimetrias de até 0,06 apresentaram frequência de 54,4 por cento e assimetrias de até 0,1 estiveram presentes em 79,7 por cento da amostra. Dois indivíduos (1,63 por cento) apresentaram assimetrias superiores a 0,2.

Conclusão:

A frequência de assimetrias no grupo de adolescentes estudado é similar à encontrada em estudos realizados com população adulta normal.
ABSTRACT

Purpose:

To determine the frequency of asymmetries greater than 0.2 in the cup-to-disc ratio of a population of adolescents.

Methods:

Fundus photographs of both eyes of 123 adolescents were digitized at the resolution of 300 pixels per inch (300 dpi), 8 bits, with a RBG color pattern. The measurements were performed using the Image J software, version 1.42, developed by the National Institutes of Health (NIH), Java platform version 1.6.

Results:

The values of the differences in the cup-to-disc ratio between the two eyes of the same individual ranged from 0 to 0.30. The mean difference was 0.07, the median 0.06 and the standard deviation 0.05. About 54.4 percent of the studied population had asymmetries up to 0.06 and 79.7 percent had asymmetries up to 0.1. Two individuals presented asymmetries of more than 0.2, corresponding to 1.63 percent of the evaluated subjects.

Conclusion:

The frequency of asymmetries in the group of adolescents studied was similar to that detected in studies of the normal adult population.
Asunto(s)

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Disco Óptico / Fondo de Ojo Tipo de estudio: Estudio observacional / Estudio de prevalencia / Factores de riesgo Límite: Adolescente / Femenino / Humanos / Masculino Idioma: Portugués Revista: Arq. bras. oftalmol Asunto de la revista: Oftalmología Año: 2010 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade de São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Disco Óptico / Fondo de Ojo Tipo de estudio: Estudio observacional / Estudio de prevalencia / Factores de riesgo Límite: Adolescente / Femenino / Humanos / Masculino Idioma: Portugués Revista: Arq. bras. oftalmol Asunto de la revista: Oftalmología Año: 2010 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade de São Paulo/BR