Severe tricuspid stenosis related to endocardial pacemaker lead / Estenose tricúspide severa induzida por eletrocatéter de marcapasso
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm
;
23(3): 119-121, jul.-set. 2010. ilus
Artículo
en Inglés
| LILACS
| ID: lil-567756
ABSTRACT
Tricuspid stenosis (TS) is an uncommon complication of transvenous ventricular pacing. We present a case of TS developed 14 years after pacemacker implantation. The etiology of stenosis appeared to be inflammation and fibrosis of tricuspid valve (TV) secondary to leaflet perforation by the pacemacker lead and it was managed successfully with surgical valvuloplasty. Iatrogenic TS may occur more frequently than is clinically suspected and it should be considered in any patient with endocardial leads presenting with right heart failure.
Texto completo:
Disponible
Índice:
LILACS (Américas)
Asunto principal:
Marcapaso Artificial
/
Estenosis de la Válvula Tricúspide
/
Insuficiencia Cardíaca
Límite:
Humanos
/
Masculino
Idioma:
Inglés
Revista:
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm
Asunto de la revista:
Cardiología
Año:
2010
Tipo del documento:
Artículo
País de afiliación:
Portugal
Institución/País de afiliación:
Association of Arrhythmology Pacing and Electrophysiology (APAPE)/PT
/
Centro Hospitalar de Trás-os-Montes-e-Alto-Douro/PT