Your browser doesn't support javascript.
loading
Uso de enxerto ósseo homólogo estrutural cortical em cirurgias de reconstrução femoral / Use of cortical structural homologous bone graft in femoral reconstructive surgery
Roos, Milton Valdomiro; Roos, Bruno Dutr; Giora, Taís Stedile Busin; Taglietti, Thiago Martins.
Afiliación
  • Roos, Milton Valdomiro; Hospital Ortopédico de Passo Fundo. Passo Fundo. BR
  • Roos, Bruno Dutr; Hospital Ortopédico de Passo Fundo. Passo Fundo. BR
  • Giora, Taís Stedile Busin; Hospital Ortopédico de Passo Fundo. Passo Fundo. BR
  • Taglietti, Thiago Martins; Hospital Ortopédico de Passo Fundo. Passo Fundo. BR
Rev. bras. ortop ; 45(5): 483-489, 2010. ilus, graf
Article en Pt | LILACS | ID: lil-567991
Biblioteca responsable: BR26.1
RESUMO

OBJETIVO:

Realizar uma avaliação clínica e radiográfica dos pacientes submetidos a tratamento cirúrgico com utilização de enxerto ósseo homólogo estrutural cortical em cirurgias de reconstrução femoral secundárias a afrouxamento de artroplastia total do quadril e fraturas periprotéticas.

MÉTODOS:

Foi realizado estudo retrospectivo com 27 pacientes submetidos a tratamento cirúrgico de reconstrução femoral secundária a afrouxamento de artroplastia total de quadril (12 casos) e fratura periprotética (15 casos) utilizando enxerto homólogo estrutural cortical e implante cimentado, no período de junho de 1999 a fevereiro de 2008. Desses, 21 preencheram todos os critérios necessários para este trabalho. Os pacientes foram submetidos a uma avaliação clínica pré e pós-operatória, de acordo com o Harris Hip Score. Foram avaliadas também radiografias pré-operatórias, pós-operatórias imediatas e tardias, comparando a consolidação das fraturas, os sinais radiográficos de consolidação do enxerto, a modificação do estoque ósseo e da qualidade óssea do fêmur e o alinhamento femoral.

RESULTADOS:

Nove pacientes (42,9 por cento) foram submetidos à reconstrução femoral secundária a afrouxamento de artroplastia total de quadril e 12 (57,1 por cento), à reconstrução femoral secundária à fratura periprotética. Com relação à classificação clínica pós-operatória, os resultados obtidos foram considerados como satisfatórios em 85,7 por cento dos casos e insatisfatórios em 14,3 por cento. Sinais radiográficos de consolidação do enxerto foram visualizados em todos os casos. Houve aumento do estoque ósseo em 90,5 por cento das reconstruções de quadril realizadas, conforme aferição do índice cortical. Além disso, a modificação da qualidade óssea femoral foi considerada boa em 66,7 por cento dos casos...
ABSTRACT

OBJECTIVE:

To perform a clinical and radiographic assessment of patients submitted to cortical structural homologous bone graftsurgical treatment for femoral reconstruction following mechanical failure of total hip arthroplasty and periprosthetic fractures.

METHODS:

A retrospective study with 27 patients submitted to surgical treatment for femoral reconstruction following mechanical failure of total hip arthroplasty (12 cases) and periprosthetic fractures (15 cases), using cortical structural homologous bone graft and cemented implants, in the period of June 1999 to February 2008 was performed. Of these, 21 fulfilled the criteria required for this study. Patients were submitted to a pre and postoperative clinical assessment according to Harris Hip Score. Pre-operative, immediate and late postoperative radiographs were also evaluated by comparing fracture consolidation, radiographic signs of graft integration, changes in bone stock and femoral bone quality, as well as femoral alignment.

RESULTS:

Nine patients (42.9 percent) were submitted to femoral reconstruction following mechanical failure of total hip arthroplasty. The other 12 cases (57.1 percent), were submitted to femoral reconstruction following periprosthetic fracture. Results were considered satisfactory in 85.7 percent and unsatisfactory in 14.3 percent of cases. Radiographic signs of graft integration to the host's bone were seen in all cases. There was an increase of bone stock in 90.5 percent of hip reconstructions, according to cortical index measurement. Furthermore, changes in femoral bone quality were considered good in 66.7 percent of cases...
Asunto(s)
Palabras clave

Texto completo: 1 Índice: LILACS Asunto principal: Trasplante Óseo / Artroplastia de Reemplazo de Cadera / Fracturas del Fémur / Prótesis de Cadera Tipo de estudio: Observational_studies Límite: Adult / Female / Humans / Male Idioma: Pt Revista: Rev. bras. ortop Asunto de la revista: ORTOPEDIA Año: 2010 Tipo del documento: Article

Texto completo: 1 Índice: LILACS Asunto principal: Trasplante Óseo / Artroplastia de Reemplazo de Cadera / Fracturas del Fémur / Prótesis de Cadera Tipo de estudio: Observational_studies Límite: Adult / Female / Humans / Male Idioma: Pt Revista: Rev. bras. ortop Asunto de la revista: ORTOPEDIA Año: 2010 Tipo del documento: Article