Non-invasive assessment of endothelial function. Intra and inter-observer variability
González, Arturo Sotomayor; Kostine, Andrea; Gómez-Flores, Jorge R; Márquez, Manlio F; Hermosillo, Antonio G; París, Juan Verdejo; Torres, Pedro Iturralde; Lizalde, Luis Colín; Townsend, Santiago Nava; Cárdenas, Manuel.
  • González, Arturo Sotomayor; Instituto Nacional de Cardiologia lgnacio Chávez. Electrocardiology Department. MX
  • Kostine, Andrea; Instituto Nacional de Cardiologia lgnacio Chávez. Electrocardiology Department. MX
  • Gómez-Flores, Jorge R; Instituto Nacional de Cardiologia lgnacio Chávez. Electrocardiology Department. MX
  • Márquez, Manlio F; Instituto Nacional de Cardiologia lgnacio Chávez. Electrocardiology Department. MX
  • Hermosillo, Antonio G; Instituto Nacional de Cardiologia lgnacio Chávez. Electrocardiology Department. MX
  • París, Juan Verdejo; Instituto Nacional de Cardiologia lgnacio Chávez. Electrocardiology Department. MX
  • Torres, Pedro Iturralde; Instituto Nacional de Cardiologia lgnacio Chávez. Electrocardiology Department. MX
  • Lizalde, Luis Colín; Instituto Nacional de Cardiologia lgnacio Chávez. Electrocardiology Department. MX
  • Townsend, Santiago Nava; Instituto Nacional de Cardiologia lgnacio Chávez. Electrocardiology Department. MX
  • Cárdenas, Manuel; Instituto Nacional de Cardiologia lgnacio Chávez. Electrocardiology Department. MX
Arch. cardiol. Méx ; 76(4): 397-400, oct.-dic. 2006.
Artículo en Inglés | LILACS | ID: lil-568609
ABSTRACT
BACKGROUND AND

OBJECTIVES:

Non-invasive evaluation of endothelial function with high resolution ultrasound has become a widely accepted tool in determination of high risk subjects for early atherosclerosis. Despite its simple appearance, ultrasonographic assessment of brachial artery changes, is technically challenging and has a significant learning curve. In the present study, we evaluate the intra and inter-observer variability in assessing peripheral endothelial function with high resolution ultrasound at a tertiary referral center.

METHODS:

Assessment of endothelial function was performed by 2 physicians in 20 volunteers without evidence of coronary artery disease. Endothelial function is evaluated with a high frequency bidimensional ultrasound with a 10.0-MHz linear-array transducer used for the study. Each volunteer was examined by both observers using an identical protocol, measuring brachial artery diameter on three occasions.

RESULTS:

Excellent correlation was observed for all brachial artery measures with a Spearman's correlation coefficient > 0.9 (p < 0.0001). Flow-mediated dilation (FMD) in the study population was of 10.45+/-6.9%. Flow independent dilation (FID) was of 24.35+/-7.63%. Intra-observer variability was of 2.1% for observer A and 1.1 % for observer B.

CONCLUSIONS:

Non-invasive assessment of endothelial function using brachial artery ultrasound is reproducible and can be performed with low intra and inter-observer variability.
Asunto(s)
Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Arteria Braquial / Endotelio Vascular Tipo de estudio: Estudios de evaluación Límite: Adulto / Femenino / Humanos / Masculino Idioma: Inglés Revista: Arch. cardiol. Méx Asunto de la revista: Cardiología Año: 2006 Tipo del documento: Artículo País de afiliación: México Institución/País de afiliación: Instituto Nacional de Cardiologia lgnacio Chávez/MX

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Arteria Braquial / Endotelio Vascular Tipo de estudio: Estudios de evaluación Límite: Adulto / Femenino / Humanos / Masculino Idioma: Inglés Revista: Arch. cardiol. Méx Asunto de la revista: Cardiología Año: 2006 Tipo del documento: Artículo País de afiliación: México Institución/País de afiliación: Instituto Nacional de Cardiologia lgnacio Chávez/MX