OBJETIVO:
Avaliar o processamento auditivo em idosos por meio do teste de resolução temporal Gaps in Noise e verificar se a presença de perda auditiva influencia no desempenho nesse teste.MÉTODOS:
Sessenta e cinco ouvintes idosos, entre 60 e 79 anos, foram avaliados por meio do teste Gaps In Noise. Para seleção da amostra foram realizados anamnese, mini-exame do estado mental e avaliação audiológica básica. Os participantes foram alocados e estudados em um grupo único e posteriormente divididos em três grupos segundo os resultados audiométricos nas frequências de 500 Hz, 1, 2, 3, 4 e 6 kHz. Assim, classificou-se o G1 com audição normal, o G2 com perda auditiva de grau leve e o G3 com perda auditiva de grau moderado.RESULTADOS:
Em toda a amostra, as médias de limiar de detecção de gap e de porcentagem de acertos foram de 8,1 ms e 52,6 por cento para a orelha direita e de 8,2 ms e 52,2 por cento para a orelha esquerda. No G1, estas medidas foram de 7,3 ms e 57,6 por cento para a orelha direita e de 7,7 ms e 55,8 por cento para a orelha esquerda. No G2, estas medidas foram de 8,2 ms e 52,5 por cento para a orelha direita e de 7,9 ms e 53,2 por cento para a orelha esquerda. No G3, estas medidas foram de 9,2 ms e 45,2 por cento para as orelhas direita e esquerda.CONCLUSÃO:
A presença de perda auditiva elevou os limiares de detecção de gap e diminuiu a porcentagem de acertos no teste Gaps In Noise.ABSTRACT
PURPOSE:
To assess the auditory processing of elderly patients using the temporal resolution Gaps-in-Noise test, and to verify if the presence of hearing loss influences the performance on this test.METHODS:
Sixty-five elderly listeners, with ages between 60 and 79 years, were assessed with the Gaps-in-Noise test. To meet the inclusion criteria, the following procedures were carried out anamnesis, mini-mental state examination, and basic audiological evaluation. The participants were allocated and studied as a group, and then were divided into three groups, according to audiometric results for the frequencies of 500 Hz, 1, 2, 3, 4 and 6 kHz. Thus, subjects in G1 had normal hearing, participants in G2 were classified with mild hearing loss, and those in G3 had moderate hearing loss.RESULTS:
In the entire sample, the mean gap detection threshold and the mean percentage of correct responses were, respectively, 8.1 ms and 52.6 percent for the right ear, and 8.2 ms and 52.2 percent for the left ear. In G1, these measures were 7.3 ms and 57.6 percent for the right ear, and 7.7 ms and 55.8 percent for the left ear. In G2, these measures were 8.2 ms and 52.5 percent for the right ear, and 7.9 ms and 53.2 percent for the left ear. In G3, the measures were 9.2 ms and 45.2 percent for the right and left ears.CONCLUSION:
The presence of hearing loss increased the gap detection thresholds and lowered the percentage of correct responses on the Gaps-in-Noise test.
Texto completo:
Disponible
Índice:
LILACS (Américas)
Asunto principal:
Percepción Auditiva
/
Trastornos de la Percepción Auditiva
/
Pérdida Auditiva
/
Pruebas Auditivas
Límite:
Adulto
/
Humanos
Idioma:
Portugués
Revista:
Rev. Soc. Bras. Fonoaudiol
Asunto de la revista:
Patología del Habla y Lenguaje
Año:
2010
Tipo del documento:
Artículo
País de afiliación:
Brasil
Institución/País de afiliación:
Hospital Central da Marinha/BR
/
Universidade Federal do Rio de Janeiro/BR
Similares
MEDLINE
...
LILACS
LIS