Your browser doesn't support javascript.
loading
Comparação de técnicas não invasivas para medir a pressão arterial em recém-nascidos / Comparison of noninvasive techniques to measure blood pressure in newborns
Ribeiro, Manoel A. S; Fiori, Humberto H; Luz, Jorge H; Piva, Jefferson P; Ribeiro, Nilza M. E; Fiori, Renato M.
  • Ribeiro, Manoel A. S; Pontifícia Universidade Católica do Rio Grande do Sul. Porto Alegre. BR
  • Fiori, Humberto H; PUCRS. Departamento de Pediatria. Porto Alegre. BR
  • Luz, Jorge H; PUCRS. Departamento de Pediatria. Porto Alegre. BR
  • Piva, Jefferson P; PUCRS. Departamento de Pediatria. Porto Alegre. BR
  • Ribeiro, Nilza M. E; s.af
  • Fiori, Renato M; PUCRS. Faculdade de Medicina. Departamento de Pediatria. Porto Alegre. BR
J. pediatr. (Rio J.) ; 87(1): 57-62, jan.-fev. 2011. graf
Artículo en Portugués | LILACS | ID: lil-576130
RESUMO
OBJETIVO: Comparar a pressão arterial pelos métodos do flush, da oximetria de pulso e da oscilometria utilizando o Doppler em neonatos. MÉTODOS: Foram realizadas medidas de pressão arterial não invasiva utilizando três métodos distintos (flush, oximetria de pulso e oscilometria automática) em três grupos de recém-nascidos selecionados por sorteio: 15 a termo e normais, 16 prematuros estáveis e 14 doentes. Todas as medidas foram filmadas, editadas separadamente, codificadas e analisadas independentemente por três neonatologistas. RESULTADOS: Realizaram-se 57 medidas por cada método. Os métodos do flush e da oximetria de pulso mostraram melhor correlação com o Doppler do que a oscilometria (coeficiente de correlação 0,89, 0,85 e 0,71, respectivamente, p < 0,01). A diferença entre as médias das medidas, seus respectivos desvios padrão e o intervalo de confiança de 95 por cento quando comparados com Doppler foram: -5,2±7,9 (-21,1:10,7) mmHg com o método do flush; 0,4±8,9 (-17,5:18,2) mmHg com a oximetria de pulso; e 6,4±16,1 (-25,8:8,6) mmHg com a oscilometria. O método do flush mostrou melhor concordância com o Doppler para diagnóstico de hipotensão do que os métodos da oximetria e da oscilometria. CONCLUSÕES: Os métodos do flush e da oximetria de pulso mostraram-se úteis para medir a pressão arterial sistólica de recém-nascidos, sendo que o método oscilométrico mostrou-se o menos concordante com o Doppler para detectar hipotensão.
ABSTRACT
OBJECTIVE: To compare blood pressure measurements in newborn infants using the flush method, pulse oximetry and oscillometry according to Doppler findings. METHODS: Noninvasive blood pressure measurements were made using three techniques (flush method, pulse oximetry and oscillometry) in three groups of newborns: 15 normal term infants, 16 stable preterm infants, and 14 critically ill infants. All measurements were video recorded, edited separately, coded and analyzed independently by three neonatologists. RESULTS: Fifty-seven measurements were made using each method. The flush method and pulse oximetry had a better correlation with Doppler findings than oscillometry (correlation coefficients: 0.89, 0.85, 0.71; p < 0.01). The difference between measurement means, their standard deviations and the 95 percent confidence intervals when compared with Doppler findings were: -5.2±7.9 (-21.1:10.7) mmHg for the flush method; 0.4±8.9 (-17.5:18.2) mmHg for pulse oximetry; and 6.4±16.1 (-25.8:8.6) mmHg for oscillometry. The flush method had a better agreement with Doppler findings for the diagnosis of hypotension than oximetry and oscillometry. CONCLUSIONS: The flush method and pulse oximetry seem to be useful techniques to measure systolic blood pressure in newborn infants; oscillometry had the poorest agreement with Doppler findings to detect hypotension.
Asunto(s)


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Determinación de la Presión Sanguínea / Hipotensión Tipo de estudio: Estudio observacional / Estudio de prevalencia / Factores de riesgo Límite: Humanos / Recién Nacido Idioma: Portugués Revista: J. pediatr. (Rio J.) Asunto de la revista: Pediatría Año: 2011 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: PUCRS/BR / Pontifícia Universidade Católica do Rio Grande do Sul/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Determinación de la Presión Sanguínea / Hipotensión Tipo de estudio: Estudio observacional / Estudio de prevalencia / Factores de riesgo Límite: Humanos / Recién Nacido Idioma: Portugués Revista: J. pediatr. (Rio J.) Asunto de la revista: Pediatría Año: 2011 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: PUCRS/BR / Pontifícia Universidade Católica do Rio Grande do Sul/BR