A comparative study of microstrain around three-morse taper implants with machined and plastic copings under axial loading
Abreu, Celina Wanderley de; Vasconcellos, Luis Gustavo Oliveira de; Balducci, Ivan; Nishioka, Renato Sussumu.
  • Abreu, Celina Wanderley de; University of Campinas. Piracicaba Dental School. Department of Prosthodontics. Piracicaba. BR
  • Vasconcellos, Luis Gustavo Oliveira de; University of Campinas. Piracicaba Dental School. Department of Dental Materials and Prosthodontics. Piracicaba. BR
  • Balducci, Ivan; São Paulo State University. São José dos Campos Dental School. Department of Community Dentistry and Pediatric Clinic. São José dos Campos. BR
  • Nishioka, Renato Sussumu; São Paulo State University. São José dos Campos Dental School. Department of Dental Materials and Prosthodontics. São José dos Campos. BR
Braz. j. oral sci ; 9(1): 11-15, Jan.-Mar. 2010. ilus, tab, graf
Artículo en Inglés | LILACS, BBO | ID: lil-578039
RESUMO

Aim:

To evaluate the occurrence of microstrain around morse taper implants in straight configuration under axial load in a cast monoblock framework.

Methods:

Three implants were inserted in a polyurethane block and microunit abutments were installed on the implants with 20 Ncm torque. Plastic and machined copings were adapted on the preset waxing to fabricate the framework (n=5). Four strain gauges were attached on the upper surface of the block and then each framework was tightened on the abutments and a vertical load of 30 kg was applied to five points of the framework.

Results:

The data obtained in the strain gauge analysis were subjected to twoway ANOVA and Tukey’s test (=0.05). There was statistically significant difference (p=0.0222) for the factor application point and the mean microstrain values were application point B 402,04µ, point A 401.21µ, point E 390.44µ, point D 341.76µand point C 309.19 µ.

Conclusions:

There was no microstrain difference between plastic and machined copings during axial loading. Difference in the application point was observed, but remained within bone physiological limits.
Asunto(s)

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Implantes Dentales / Prótesis Dental de Soporte Implantado / Análisis del Estrés Dental / Dentadura Parcial Fija Idioma: Inglés Revista: Braz. j. oral sci Asunto de la revista: Odontología Año: 2010 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: São Paulo State University/BR / University of Campinas/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Implantes Dentales / Prótesis Dental de Soporte Implantado / Análisis del Estrés Dental / Dentadura Parcial Fija Idioma: Inglés Revista: Braz. j. oral sci Asunto de la revista: Odontología Año: 2010 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: São Paulo State University/BR / University of Campinas/BR