A laserterapia de baixa potência melhora o desempenho muscular mensurado por dinamometria isocinética em humanos / Low-level laser therapy enhances muscular performance as measured by isokinetic dynamometry in humans
Fisioter. pesqui
;
17(4): 317-321, out.-dez. 2010. ilus, graf
Artículo
en Portugués
| LILACS
| ID: lil-587973
RESUMO
A fadiga muscular é uma nova área de pesquisa em laserterapia, com poucos estudos conduzidos. Embora a laserterapia de baixa potência (LBP) previamente ao exercício tenha apresentado resultados positivos no retardo da fadiga musculoesquelética, ainda não foi estudada utilizando-se a dinamometria isocinética para mensurar desempenho e fadiga muscular. Este estudo tem o objetivo de avaliar os efeitos da LBP (655 nm, 50 mW, 2,4 J por ponto e 12 J de energia total) sobre o desempenho e fadiga muscular do músculo tibial anterior, utilizando dinamometria isocinética (30 repetições de contração concêntrica) em 14 indivíduos saudáveis sedentários do sexo masculino. Os voluntários foram avaliados ao efetuar 30 repetições isocinéticas de dorsiflexão de tornozelo à velocidade angular de 240°.seg-1. Os resultados mostram que, quando os voluntários foram tratados com LBP antes do exercício, os valores do pico de torque (30,91±5,86 N.m) foram significativamente superiores, comparados a três medições anteriores sem a aplicação de LBP (24,92±7,45 N.m, p<0,001; 26,83±7,74 N.m, p<0,01; e 26,00±7,88 N.m, p<0,001, respectivamente). Não foi observada redução no índice de fadiga. Conclui-se que a LBP aumenta o torque gerado pelos músculos irradiados, melhorando assim o desempenho musculoesquelético, porém sem interferir no índice de fadiga.
ABSTRACT
Skeletal muscle fatigue is a novel research area in laser therapy, there being few studies carried out. Though low-level laser therapy (LLLT) applied prior to exercise has showed positive results in delaying skeletal muscle fatigue, no studies could be found that measured muscle performance and fatigue by means of isokinetic dynamometry. This clinical trial aims at assessing the effects of LLLT (655 nm, 50 mW and 12 J total energy delivered) on anterior tibialis muscle performance and fatigue by means of isokinetic dynamometry (30 concentric-mode repetitions at 240º.sec-1 angular speed) in 14 healthy male subjects. Results show that, when volunteers had been treated with LLLT prior to exercise, torque peak values (30.91±5.86 N.m) were significantly higher than those of three previous measurements with no LLLT (24.92±7.45 N.m, p<0.001; 26.83±7.74 N.m, p<0.01; and 26.00±7.88 N.m, p<0.001). However, no decrease in fatigue indexes could be found. It may thus be said that LLLT increased skeletal muscle torque in irradiated muscles, but had no effect on muscle fatigue.
Texto completo:
Disponible
Índice:
LILACS (Américas)
Asunto principal:
Fatiga Muscular
/
Terapia por Luz de Baja Intensidad
/
Dinamómetro de Fuerza Muscular
/
Hombres
Límite:
Adulto
/
Humanos
/
Masculino
Idioma:
Portugués
Revista:
Fisioter. pesqui
Asunto de la revista:
MEDICINA FISICA E REABILITACAO
Año:
2010
Tipo del documento:
Artículo
País de afiliación:
Brasil
/
Noruega
Institución/País de afiliación:
Universdade de Bergen/NO
/
Universidade Nove de Julho/BR
/
Universidade Paulista/BR
/
Universidade de São Paulo/BR
Similares
MEDLINE
...
LILACS
LIS