Repeatability of the evaluation of systemic microvascular endothelial function using laser doppler perfusion monitoring: clinical and statistical implications
Clinics
;
66(4): 599-605, 2011. graf, tab
Artículo
en Inglés
| LILACS
| ID: lil-588910
ABSTRACT
OBJECTIVE:
An awareness of the repeatability of biological measures is required to properly design and calculate sample sizes for longitudinal interventional studies. We investigated the day-to-day repeatability of measures of systemic microvascular reactivity using laser Doppler perfusion monitoring.METHODS:
We performed laser Doppler perfusion monitoring in combination with skin iontophoresis using acetylcholine and sodium nitroprusside as well as post-occlusive reactive and thermal hyperemia twice within two weeks. The repeatability was assessed by calculating the within-subject standard deviations, limits of agreement, typical errors and intra-class correlation coefficients between days 1 and 2. The ratio of the within-subject standard deviation to the mean values obtained on days 1 and 2 (within-subject standard deviation/GM) was used to determine the condition with the best repeatability.RESULTS:
Twenty-four healthy subjects, aged 24.6 + 3.8 years, were recruited. The area under the curve of the vasodilatory response to post-occlusive reactivity showed marked variability (within-subject standard deviation/GM = 0.83), while the area under the curve for acetylcholine exhibited less variability (within-subject standard deviation/ GM = 0.52) and was comparable to the responses to sodium nitroprusside and thermal treatment (within-subject standard deviations/GM of 0.67 and 0.56, respectively). The area under the blood flow/time curve for vasodilation during acetylcholine administration required the smallest sample sizes, the area under the blood flow/time curve during post-occlusive reactivity required the largest sample sizes, and the area under the blood flow/time curves of vasodilation induced by sodium nitroprusside and thermal treatment required intermediate sizes.CONCLUSIONS:
In view of the importance of random error related to the day-to-day repeatability of laser Doppler perfusion monitoring, we propose an original and robust statistical methodology for use in designing prospective clinical studies.
Texto completo:
Disponible
Índice:
LILACS (Américas)
Asunto principal:
Piel
/
Endotelio Vascular
/
Iontoforesis
/
Flujometría por Láser-Doppler
/
Microcirculación
Tipo de estudio:
Estudio observacional
/
Estudio de prevalencia
/
Estudio pronóstico
/
Factores de riesgo
Límite:
Adulto
/
Femenino
/
Humanos
/
Masculino
Idioma:
Inglés
Revista:
Clinics
Asunto de la revista:
Medicina
Año:
2011
Tipo del documento:
Artículo
País de afiliación:
Brasil
Institución/País de afiliación:
Fiocruz/BR
/
State University of Rio de Janeiro/BR
Similares
MEDLINE
...
LILACS
LIS