Caracterização da curva da frequência cardíaca durante teste incremental máximo em esteira / Characterization of the heart rate curve during a maximum incremental test on a treadmill
Rev. bras. cineantropom. desempenho hum
;
13(4): 285-291, July-Aug. 2011. ilus, graf, tab
Artículo
en Portugués
| LILACS
| ID: lil-599888
RESUMO
O propósito deste estudo foi analisar o comportamento da frequência cardíaca (FC) versus a carga de trabalho crescente (CTC) em teste de esteira, utilizando três modelos matemáticos (linear, linear com dois segmentos de reta e sigmóide) e verificar qual o melhor modelo que possibilita a identificação de um limiar de FC que pudesse servir de preditor para os limiares ventilatórios (LV1 e LV2). Vinte e dois homens realizaram um teste incremental (re-teste n=12), com velocidade inicial de 5,5 km.h-1 e incrementos de 0,5 km.h-1 a cada minuto, até a exaustão. Medidas contínuas de FC e trocas gasosas foram convertidas para médias de 5 e 20 segundos. Somatória dos resíduos quadrados e quadrado médio do erro foram usados para verificar o melhor ajuste. A relação FC/CTC foi melhor representada pelo modelo Lin2 no grupo teste e re-teste (p<0,05). Foi possível identificar um ponto de deflexão de FC, utilizando o modelo Lin2 (limiar de FC) em todos os indivíduos no teste (164 ± 16,6 bpm; 83,6 por cento FC MÁX) e no re-teste (162 ± 20,0 bpm; 83,9 por cento FC MÁX). O limiar de FC (Lin2PDFC) ocorreu a 9,2 ± 1,3 km.h-1 (67,9 por cento VelMÁX) e foi menor que o LV2 (LV2= 10,6 ± 1,5 km.h-1; 77,3 por cento VelMÁX; p< 0,05), mas não diferente de LV1 (8,4 ± 1,2 km.h-1; 61,6 por cento VelMÁX; p> 0,05). Durante teste incremental em esteira, a relação FC/CTC parece ser bem descrita por uma função linear com 2 segmentos de reta, a qual permite a determinação de um limiar de FC que se aproxima do LV1.
ABSTRACT
The objective of this study was to analyze the heart rate (HR) profile plotted against incremental workloads (IWL) during a treadmill test using three mathematical models [linear, linear with 2 segments (Lin2), and sigmoidal], and to determine the best model for the identification of the HR threshold that could be used as a predictor of ventilatory thresholds (VT1 and VT2). Twenty-two men underwent a treadmill incremental test (retest group n=12) at an initial speed of 5.5 km.h-1, with increments of 0.5 km.h-1 at 1-min intervals until exhaustion. HR and gas exchange were continuously measured and subsequently converted to 5-s and 20-s averages, respectively. The best model was chosen based on residual sum of squares and mean square error. The HR/IWL ratio was better fitted with the Lin2 model in the test and retest groups (p<0.05). The Lin2 model permitted the identification of the HR threshold (Lin2HRDP) in all subjects of the test (164 ± 16.6 bpm; 83.6 percent HR MAX) and retest groups (162 ± 20.0 bpm; 83.9 percent HR MAX). Lin2HRDP (9.2 ± 1.3 km.h-1; 67.9 percent speedMAX) was lower than VT2 (10.6 ± 1.5 km.h-1, 77.3 percent speedMAX; p<0.05), but did not differ from VT1 (8.4 ± 1.2 km.h-1, 61.6 percent speedMAX; p>0.05). During a treadmill incremental test, the HR/IWL ratio seems to be better fitted with a Lin2 model, which permits to determine the HR threshold that coincides with VT1.
Texto completo:
Disponible
Índice:
LILACS (Américas)
Tipo de estudio:
Estudio pronóstico
/
Estudio de tamizaje
Idioma:
Portugués
Revista:
Rev. bras. cineantropom. desempenho hum
Asunto de la revista:
Educación Física
/
Medicina Deportiva
/
MEDICINA FISICA E REABILITACAO
Año:
2011
Tipo del documento:
Artículo
País de afiliación:
Brasil
Institución/País de afiliación:
Universidade Federal de Alagoas/BR
/
Universidade de São Paulo/BR
Similares
MEDLINE
...
LILACS
LIS