Desenvolvimento, caracterização e avaliação de uma superfície de implante microtexturizada / Development, characterization and evaluation of a microtextured implant surface
Full dent. sci
;
1(2): 135-141, Aug. 15, 2010.
Artículo
en Portugués
| LILACS, BBO
| ID: lil-605596
RESUMO
Com o objetivo de desenvolver, caracterizar e avaliar uma superfície microtexturizada de implantes propôs-se a realização deste estudo primeiramente laboratorial, através da Microscopia Eletrônica de Varredura (MEV) e microanálise por Energia de Dispersão (EDS) e, em um segundo estágio in vivo em animais. Para isso, foram fornecidos pela empresa Implacil Materiais Odontológicos (Implantes DeBortoli) 24 implantes cilíndricos, os quais foram divididos em dois grupos 1 Implantes jateados por TiO; 2 Implantes jateados e microtexturizados por imersão em ácido Fluorídrico. Os resultados demonstraram que na primeira fase os implantes avaliados em MEV do grupo 2 tiveram uma morfologia superficial muito mais uniforme e regular que o grupo 1. Na análise por EDS também o grupo 2 apresentou um melhor resultado, não sendo identificado nenhum tipo de contaminante em suas amostras, diferentemente do grupo 1 o qual tivemos a presença de Alumínio. Na segunda fase em que foram utilizados seis coelhos, que receberam 2 implantes em cada tíbia, foi observado o índice de tecido ósseo corticalizado em contato com a superfície, após oito semanas, tivemos um índice médio de 37,10% no grupo 1 e 58,73% no grupo 2. Em conclusão podemos verificar que é possível controlar físico-quimicamente a microtexturização superficialdos implantes e que isso além de dar uma conformação mais uniforme a superfície, elimina a possibilidade de contaminantes, aumentando o índice de osteointegração e formação de tecido ósseo corticalizado.
ABSTRACT
In order to develop, characterize and to evaluate a microtextured surface implant proposed to achieve this first laboratory study by Scanning Electron Microscopy (SEM) and microanalysis by energy dispersion (EDS), and a second stage in vivo in animals. For this they were supplied by the company Implacil - Dental Materials (Implants Debortoli) 24 cylindrical implants, which were divided into two groups 1 - Implants blasted by TiO, 2 - and microtextured blasted implants byimmersion in hydrofluoric acid. The results showed that the first phase the implants evaluated in the SEM group 2 had a surface morphology much more uniform and regular than group 1.The analysis by EDS also in group 2 was better, but no identification of any contaminant in their samples was found, in contrast to group 1 which had the presence of aluminum. In the second phase six rabbits were used receiving 2 implants in each tibia. It was observed the rate of bone corticalization in contact with the surface, after eight weeks, had an average rate of 37.10% in group 1 and 58 73% in group 2. In conclusion we can see that you can control the physical and chemical microtexturization of the surface of implants and that it gives a more uniform forming surface, eliminates the possibility of contaminants, increasing the rate of osseointegration andformation of bone cortical tissue.
Buscar en Google
Índice:
LILACS (Américas)
Asunto principal:
Titanio
/
Implantes Dentales
/
Oseointegración
/
Implantación Dental Endoósea
Tipo de estudio:
Estudios de evaluación
Límite:
Animales
Idioma:
Portugués
Revista:
Full dent. sci
Asunto de la revista:
Odontología
Año:
2011
Tipo del documento:
Artículo
País de afiliación:
Brasil
/
Uruguay
Institución/País de afiliación:
Pontifícia Universidade Católica do Rio Grande do Sul/BR
/
Universidade Católica do Uruguai/UY
/
Universidade Federal de Santa Maria/BR
Similares
MEDLINE
...
LILACS
LIS