Your browser doesn't support javascript.
loading
Caracterização química e metalográfica dos aços inoxidáveis de implantes removidos de pacientes / Chemical and metallographic characterization of stainless steel in implants removed from patients
Silva, Elison da Fonseca e; Oliveira, Luiz Fernando Cappa de.
  • Silva, Elison da Fonseca e; s.af
  • Oliveira, Luiz Fernando Cappa de; Universidade Federal de Juiz de Fora. Departamento de Química. Juiz de Fora. BR
Acta ortop. bras ; 19(5): 280-285, 2011. ilus
Artículo en Portugués | LILACS | ID: lil-608419
RESUMO

OBJETIVO:

Este trabalho estudou a composição química e metalográfica (microestrutura, tamanho de grão, teor de inclusões) de aços inoxidáveis austeníticos, desenvolvidos para aplicações como biomateriais, utilizados na fabricação de implantes ortopédicos.

MÉTODO:

Foram analisados doze implantes removidos de pacientes afetados por quadro inflamatório. As análises químicas foram desenvolvidas pelas técnicas Espectrometria de Emissão Ótica e Microanálise por Dispersão de Energia (EDS) e o tamanho de grão foi determinado por microscopia ótica e Microscopia Eletrônica de Varredura (MEV) conforme norma ASTM E 1382 97.

RESULTADOS:

Observou-se que, todos os implantes apresentavam tamanho de grão superior ao recomendado pela norma, constatou-se também a presença de ferrita delta em dez dos doze implantes removidos, que de acordo com a norma ASTM F138-92 não deveriam ser percebidas microscopicamente com um aumento de 100 vezes.

CONCLUSÕES:

Em oito casos existe forte indicação de que as inflamações foram desencadeadas pela corrosão por pite. Nivel de Evidência III, Revisão sistemática de Estudos .
ABSTRACT

OBJECTIVE:

This study examines the chemical and metallographic composition (microstructure, grain size, inclusion content) of austenitic stainless steel developed as biomaterials for used in the manufacture of orthopedic implants.

METHOD:

An analysis was carried out of twelve implants removed from patients affected by inflammation. Chemical analyses were carried out using Optical Emission Spectrometry and Energy Dispersive Microanalysis (EDS), and the grain size was determined by optical microscopy and scanning electron microscopy (SEM) according to ASTM Standard E 1382 97.

RESULTS:

It was observed that all the implants had a larger grain size than is recommended by the Standard. The presence of delta ferrite was also observed in ten of the twelve implants removed, which according to ASTM Standard F138-92, should not be perceived microscopically under magnification of 100x.

CONCLUSIONS:

In eight cases, there is a strong indication that the inflammation was triggered by pitting corrosion. Level of Evidence Level III, Systematic review of studies.
Asunto(s)


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Acero Inoxidable / Materiales Biocompatibles / Tornillos Óseos / Implantación de Prótesis / Fenómenos Químicos Límite: Humanos País/Región como asunto: America del Sur / Brasil Idioma: Portugués Revista: Acta ortop. bras Asunto de la revista: Ortopedia Año: 2011 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade Federal de Juiz de Fora/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Acero Inoxidable / Materiales Biocompatibles / Tornillos Óseos / Implantación de Prótesis / Fenómenos Químicos Límite: Humanos País/Región como asunto: America del Sur / Brasil Idioma: Portugués Revista: Acta ortop. bras Asunto de la revista: Ortopedia Año: 2011 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade Federal de Juiz de Fora/BR