Cálculo de Kt/V em hemodiálise: comparação entre fórmulas / Calculation of Kt/V in haemodialysis: a comparison between the formulas
J. bras. nefrol
;
34(1): 22-26, jan.-fev.-mar. 2012. tab
Artículo
en Portugués
| LILACS
| ID: lil-623351
RESUMO
INTRODUÇÃO:
A qualidade da diálise oferecida aos pacientes em diálise pode ser mensurada pelo Kt/V, o qual pode ser calculado de diversas maneiras.OBJETIVO:
Comparar os resultados de Kt/V obtidos por meio das fórmulas de Lowrie (L) e de Daugirdas (D) com os resultados mensurados pelo monitor de clearence on-line - Online Clearence Monitor (OCM).MÉTODO:
Estudo observacional transversal com 59 pacientes em hemodiálise (HD). Os dados foram coletados na mesma sessão de diálise (ureia pré-diálise e pós-diálise) e o resultado de Kt/V foi obtido pelo OCM da máquina Fresenius 4008S (Fresenius Medical Care AG, Bad Homburg, Alemanha).RESULTADO:
Foram analisadas 95 sessões, em que prevaleceu o sexo masculino, 56% (33), com idade média de 57 + 14 anos. A hipertensão arterial com 42% (25), diabetes com 12% (7) e glomerulonefrite com 8% (5) foram as causas mais frequentes da doença renal crônica (DRC). O Kt/V médio obtido pela fórmula de L, de D e pelo OCM foi de 1,31; 1,41 e 1,32, respectivamente. A comparação entre as fórmulas de L e D mostra que há diferença estatística p = 0,008 com a correlação de Pearson de 0,950. Entre D e OCM a diferença também é significativa p = 0,011 e r = 0,346, provavelmente devido a perda convectiva, avaliada pela equação de D e não observadas por OCM e L. A comparação entre L e OCM não foi significativa p = 0,999 e r = 0,577.CONCLUSÃO:
Os dados sugerem que o OCM pode ser utilizado como um norteador para ajuste da dose de diálise em tempo real.ABSTRACT
INTRODUCTION:
The quality of delivered dialysis can be measured by the Kt/V ratio, which can be calculated in various ways.OBJECTIVE:
To compare the Kt/V ratio obtained with the formulas of Lowrie (L) and Daugirdas (D) with the results measured by an Online Clearance Monitor (OCM).Method:
Observational, cross-sectional study of 59 patients on hemodialysis (HD). Data were collected in the same dialysis session (predialysis and postdialysis urea) and Kt/V was calculated by the OCM of the Fresenius 4008S machine (Fresenius Medical Care AG, Bad Homburg, Germany).RESULTS:
A total of 95 sessions were assessed, with a predominance of males 56% (33), and a sample mean age of 57 + 14 years. Hypertension (42%; n = 25), diabetes (12%; n = 7) and glomerulonephritides (8%; n = 5) were the most frequent causes of chronic kidney disease (CKD). Mean Kt/V values obtained with the L and D formulas and the OCM were 1.31, 1.41 and 1.32, respectively. Comparison between the L and D formulas showed a statistically significant difference (p = 0.008), with a Pearson's correlation of 0.950. The difference between the D formula and the OCM was also significant (p = 0.011 and r = 0.346), probably due to convective loss, estimated by the D formula but not by the OCM and L formula. The difference between the L formula and the OCM was not significant (p = 0.999 and r = 0.577).CONCLUSION:
These data suggest that the OCM can be used as a guide to the real-time adjustment of the dialysis dose.
Texto completo:
Disponible
Índice:
LILACS (Américas)
Asunto principal:
Soluciones para Hemodiálisis
/
Diálisis Renal
/
Cálculo de Dosificación de Drogas
Tipo de estudio:
Estudio observacional
/
Estudio de prevalencia
/
Factores de riesgo
Límite:
Femenino
/
Humanos
/
Masculino
Idioma:
Portugués
Revista:
J. bras. nefrol
Asunto de la revista:
Nefrología
Año:
2012
Tipo del documento:
Artículo
País de afiliación:
Brasil
Institución/País de afiliación:
Clínica de Doenças Renais de Porto Alegre/BR
Similares
MEDLINE
...
LILACS
LIS