Your browser doesn't support javascript.
loading
CPAP em selo d'água versus CPAP com fluxo variável em recém-nascidos com desconforto respiratório: um ensaio controlado randomizado / Bubble CPAP versus CPAP with variable flow in newborns with respiratory distress: a randomized controlled trial
Yagui, Ana Cristina Zanon; Vale, Luciana Assis Pires Andrade; Haddad, Luciana Branco; Prado, Cristiane; Rossi, Felipe de Souza; Deutsch, Alice D'Agostini; Rebello, Celso Moura.
  • Yagui, Ana Cristina Zanon; Hospital Israelita Albert Einstein. Department of Maternal and Child. São Paulo. BR
  • Vale, Luciana Assis Pires Andrade; Hospital Israelita Albert Einstein. Department of Maternal and Child. São Paulo. BR
  • Haddad, Luciana Branco; Hospital Israelita Albert Einstein. Department of Maternal and Child. São Paulo. BR
  • Prado, Cristiane; Hospital Israelita Albert Einstein. Department of Maternal and Child. São Paulo. BR
  • Rossi, Felipe de Souza; Hospital Israelita Albert Einstein. Neonatal Intensive Care Unit. São Paulo. BR
  • Deutsch, Alice D'Agostini; Hospital Israelita Albert Einstein. NICU. São Paulo. BR
  • Rebello, Celso Moura; Hospital Israelita Albert Einstein. NICU. São Paulo. BR
J. pediatr. (Rio J.) ; 87(6): 499-504, nov.-dez. 2011. tab
Artículo en Portugués | LILACS | ID: lil-623443
RESUMO
OBJETIVO: Avaliar a eficácia e segurança da pressão positiva contínua na via aérea (CPAP) utilizando aparelhos de fluxo variável e fluxo contínuo em selo d'água, quanto a falha do CPAP, ocorrência de escape de ar, tempo de uso de CPAP e de oxigênio e tempo de internação em unidade de terapia intensiva e hospitalar em neonatos com desconforto respiratório (DR) moderado e peso de nascimento (PN) > 1.500 g. MÉTODOS: Quarenta recém-nascidos que necessitavam de CPAP foram randomizados em dois grupos: um grupo tratado com fluxo variável (FV) e outro com fluxo contínuo (FC). O estudo foi realizado entre outubro de 2008 e abril de 2010. Foram registrados dados demográficos, falha do CPAP, ocorrência de escape de ar, tempo de uso de CPAP e de oxigênio, entre outros. Os desfechos categóricos foram analisados com o teste do qui-quadrado ou exato de Fisher e as variáveis contínuas com o teste de Mann-Whitney, com significância de p < 0,05. RESULTADOS: Não houve diferença quanto aos dados demográficos, falha do CPAP (21,1 e 20,0% para o FV e o FC, respectivamente; p = 1,000), síndrome de escape de ar (10,5 e 5,0%, respectivamente; p = 0,605), tempo de CPAP [mediana: 22,0 h, intervalo interquartil (IIQ): 8,00-31,00 h e mediana: 22,0 h, IIQ: 6,00-32,00 h, respectivamente; p = 0,822), e tempo de uso de oxigênio (mediana: 24,00 h, IIQ:7,00-85,00 h e mediana: 21,00 h, IIQ:9,50-66,75 h, respectivamente; p = 0,779). CONCLUSÃO: Em recém-nascidos com PN > 1.500 g e DR moderado, o CPAP nasal com fluxo contínuo apresentou os mesmos benefícios do CPAP nasal com fluxo variável.
ABSTRACT
OBJECTIVE: To evaluate the efficacy and safety of nasal continuous positive airway pressure (NCPAP) using devices with variable flow or bubble continuous positive airway pressure (CPAP) regarding CPAP failure, presence of air leaks, total CPAP and oxygen time, and length of intensive care unit and hospital stay in neonates with moderate respiratory distress (RD) and birth weight (BW) > 1,500 g. METHODS: Forty newborns requiring NCPAP were randomized into two study groups: variable flow group (VF) and continuous flow group (CF). The study was conducted between October 2008 and April 2010. Demographic data, CPAP failure, presence of air leaks, and total CPAP and oxygen time were recorded. Categorical outcomes were tested using the chi-square test or the Fisher's exact test. Continuous variables were analyzed using the Mann-Whitney test. The level of significance was set at p < 0.05. RESULTS: There were no differences between the groups with regard to demographic data, CPAP failure (21.1 and 20.0% for VF and CF, respectively; p = 1.000), air leak syndrome (10.5 and 5.0%, respectively; p = 0.605), total CPAP time (median: 22.0 h, interquartile range [IQR]: 8.00-31.00 h and median: 22.0 h, IQR: 6.00-32.00 h, respectively; p = 0.822), and total oxygen time (median: 24.00 h, IQR: 7.00-85.00 h and median: 21.00 h, IQR: 9.50-66.75 h, respectively; p = 0.779). CONCLUSION: In newborns with BW > 1,500 g and moderate RD, the use of continuous flow NCPAP showed the same benefits as the use of variable flow NCPAP.
Asunto(s)


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Síndrome de Dificultad Respiratoria del Recién Nacido / Presión de las Vías Aéreas Positiva Contínua Tipo de estudio: Ensayo Clínico Controlado Límite: Femenino / Humanos / Masculino / Recién Nacido Idioma: Portugués Revista: J. pediatr. (Rio J.) Asunto de la revista: Pediatría Año: 2011 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Hospital Israelita Albert Einstein/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Síndrome de Dificultad Respiratoria del Recién Nacido / Presión de las Vías Aéreas Positiva Contínua Tipo de estudio: Ensayo Clínico Controlado Límite: Femenino / Humanos / Masculino / Recién Nacido Idioma: Portugués Revista: J. pediatr. (Rio J.) Asunto de la revista: Pediatría Año: 2011 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Hospital Israelita Albert Einstein/BR