Non heart beating organ donor: new experimental model in pigs / Doador de coração parado: novo modelo experimental em suínos
Acta cir. bras
; 27(5): 306-310, May 2012. ilus, graf
Article
en En
| LILACS
| ID: lil-626244
Biblioteca responsable:
BR1.1
ABSTRACT
PURPOSE:
To describe technical aspects of a new experimental model that simulates a non heart beating organ donor.METHODS:
Landrace pigs were operated on and cardiac arrest was obtained by means of myocardial infarction and interruption of ventilator support.RESULTS:
Mean cardiac frequency, systolic and diastolic blood pressure levels, central venous pressure, oxygen saturation and concentration of expired CO2 dropout occurred at seven minutes after cardiac arrest.CONCLUSION:
The procedure was easily reproduced and a homogeneous circulatory failure could de obtained by the end of seven minutes. The model is suitable for further studies regarding abdominal organ transplantation.RESUMO
OBJETIVO:
Descrever os aspectos técnicos de um novo modelo experimental que simula um doador de órgãos após a parada cardíaca.MÉTODOS:
Suínos da raça Landrace foram operados e a parada cardíaca foi obtida por meio de infarto do miocárdio e interrupção do suporte ventilatório.RESULTADOS:
Freqüência cardíaca, pressão arterial sistólica e diastólica, pressão venosa central, saturação de oxigênio e concentração parcial de CO2 são consistentes com falência hemodinâmica ao final de sete minutos.CONCLUSÕES:
O procedimento foi facilmente executado e uma falência circulatória pode ser obtida ao final de sete minutos. Este modelo é adequado para estudos posteriores com respeito a preservação e tranplantes de órgãos abdominais.Palabras clave
Texto completo:
1
Índice:
LILACS
Asunto principal:
Preservación de Órganos
/
Donantes de Tejidos
/
Modelos Animales
/
Paro Cardíaco
Límite:
Animals
Idioma:
En
Revista:
Acta cir. bras
Asunto de la revista:
CIRURGIA GERAL
/
Procedimentos Cir£rgicos Operat¢rios
Año:
2012
Tipo del documento:
Article