Your browser doesn't support javascript.
loading
Diferencia veno-arterial de dióxido de carbono como predictor de gasto cardiaco disminuido en modelo pediátrico experimental / Veno-arterial difference of carbondioxide as a predictor of low cardiac output in an experimental pediatric model
Díaz, Franco; Donoso, Alejandro; Carvajal, Cristóbal; Salomón, Tatiana; Torres, María; Erranz, Benjamín; Cruces, Pablo.
  • Díaz, Franco; Clínica Alemana. UCI Pediátrica. Santiago. CL
  • Donoso, Alejandro; Hospital Padre Hurtado. UCI Pediátrica. Santiago. CL
  • Carvajal, Cristóbal; Universidad del Desarrollo-Clínica Alemana. Facultad de Medicina. Instituto de Ciencias. Santiago. CL
  • Salomón, Tatiana; Clínica Alemana. UCI Pediátrica. Santiago. CL
  • Torres, María; Clínica Alemana. UCI Pediátrica. Santiago. CL
  • Erranz, Benjamín; Universidad del Desarrollo-Clínica Alemana. Facultad de Medicina. Instituto de Ciencias. Santiago. CL
  • Cruces, Pablo; Hospital Padre Hurtado. UCI Pediátrica. Santiago. CL
Rev. méd. Chile ; 140(1): 39-44, ene. 2012. ilus
Artículo en Español | LILACS | ID: lil-627605
ABSTRACT

Background:

Cardiac output (CO) measurement is not a standard of care for critically ill children, but it can be estimated by indirect methods such as veno-arterial pCO2 difference (ΔVACO2).

Aim:

To determine the correlation between CO and ΔVACO2 and evaluate the usefulness of ΔVACO2 in the diagnosis of low CO in an experimental pediatric model. Materials and

Methods:

Thirty piglets weighing 4.8 ± 0.35 kg were anesthetized and monitored with transpulmonary thermodilution. Lung injury was induced with tracheal instillation of Tween 20®. Serial measurements of central venous and arterial blood gases, as well as CO, were obtained at baseline, 1, 2 and 4 h after lung injury induction. Low cardiac output (LCO) was defined as CO lower than 2.5 Llminlm².

Results:

There was an inverse correlation between CO and ΔVACO2 (r = -0.36, p < 0.01). ΔVACO2 was 14 ± 8 mmHg in LCO state and 8 ± 6 mmHg when this condition was not present (p < 0.01). Area under the receiver operating characteristic (ROC) curves of ΔVACO2 and LCO state was 0.78 (0.68-0.86). The best cut-point was 8.9 mmHg to determine LCO with a sensibility 0.78, specificity 0.7, positive predictive value 0.27 and negative predictive value 0.96.

Conclusions:

In this model there was an inverse correlation between ΔVACO2 and CO. The best cutoff value to discard LCO was ΔVACO2 of 8.9 mmHg, indicating that under this value the presence of LCO is very unlikely.
Asunto(s)


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Dióxido de Carbono / Gasto Cardíaco Bajo / Lesión Pulmonar Aguda Tipo de estudio: Estudio diagnóstico / Evaluación Económica en Salud / Estudio pronóstico / Factores de riesgo Límite: Animales Idioma: Español Revista: Rev. méd. Chile Asunto de la revista: Medicina Año: 2012 Tipo del documento: Artículo / Documento de proyecto País de afiliación: Chile Institución/País de afiliación: Clínica Alemana/CL / Hospital Padre Hurtado/CL / Universidad del Desarrollo-Clínica Alemana/CL

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponible Índice: LILACS (Américas) Asunto principal: Dióxido de Carbono / Gasto Cardíaco Bajo / Lesión Pulmonar Aguda Tipo de estudio: Estudio diagnóstico / Evaluación Económica en Salud / Estudio pronóstico / Factores de riesgo Límite: Animales Idioma: Español Revista: Rev. méd. Chile Asunto de la revista: Medicina Año: 2012 Tipo del documento: Artículo / Documento de proyecto País de afiliación: Chile Institución/País de afiliación: Clínica Alemana/CL / Hospital Padre Hurtado/CL / Universidad del Desarrollo-Clínica Alemana/CL